CHAPTER 6
52
SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual
FLOW MONITOR SENSOR
Perform the following procedure to replace the flow monitor sensor (P/N 063-0173-492).
FIGURE 6. Pump Head and Flow Monitor Sensor
1. Disconnect the sensor cable from the motor control cabling.
2. Loosen the locking nut on the switch assembly and remove the old sensor assembly from the pump head.
3. Loosen the sensor bracket mounting screws enough to allow the bracket to slide freely on the pump head.
ADJUSTING THE STANDARD FLOW MONITOR SENSOR AND BRACKET
Pump Flow
Monitor Sensor
Pump Flow
Monitor Sensor