4
016-0230-129 Rev. B
23
SENSOR INSTALLATION
FIGURE 4. Left Inner Boom Sensor Installed
4. If optional inner boom sensors are being installed, repeat the steps above to mount the inner boom sensors to
the front of the boom.
NOTE:
Ensure that the sensor does not contact the inner boom section when the boom is folded in toward
the cab.
MOUNT THE CENTER SENSOR
FIGURE 5. Center Sensor Installed
1. Install the remaining ultrasonic sensor (P/N 063-0130-012) on the remaining ultrasonic sensor mounting
bracket (P/N 107-0172-501) using four 3/8”-16 x 1-1/4” hex bolts (P/N 311-0054-081) and four 3/8”-16 zinc
flanged lock nuts (P/N 312-1001-164).
2. Mount the center sensor assembly to the right side of the center rack using two 2-9/16” W x 4” L x 3/8” thread
U-bolts (P/N 107-0172-645) and four 3/8”-16 zinc flanged lock nuts (P/N 312-1001-164).