016-0230-129 Rev. B
31
WIRING INSTALLATION
FIGURE 7. CAN Terminator Connected to AutoBoom Harness Cable
3. Connect the CAN terminator to the CAN connection on the harness cable (P/N 115-0230-032).
4. Connect the AutoBoom harness cable CAN connection to the open CAN connection on the machine harness.
FIGURE 8. CAN and Aux Power Connections
1. Locate the existing auxiliary power connectors on the center boom section, near the flow meter and filter.
2. Connect the AUX POWER connector to the AUX POWER connector on the AutoBoom harness cable.
AUX POWER