PAGE 16/36 |
Installation manual
|
016-8000-028EN
|
Rev. B
Raven Industries Inc.
CRX/ ROS INSTALLATION | CRX/VIPER 4+ ROS - RS1 | RAVEN EUROPE GENERIC
•
Mount a pressure gauge, by making use of a t-
piece in the pressure line between the
hydraulic pump and the manifold.
•
Loosen the locking nut of the pressure relief
valve.
•
Loosen the pressure relief valve two turns
counter clockwise.
•
Steer the front wheels to one side, using the
Left/Right buttons of the CRx/ ROS.
Keep steering until the maximum pressure is
reached.
•
Read out the value on the pressure gauge.
•
Adjust the pressure relief valve until the
pressure is equal to the pressure it was before
mounting the manifold.
•
Secure the pressure relief valve with the
locking nut.
1.2.5
HYDRAULIC INSTALLATION OPEN CENTER
The manifold v3 open center consists of the standard
load sense manifold v3 with an add-on open center
part (Figure 9). Ensure the add-on is mounted the
correct way.
The pressure line that normally runs from the hydraulic
pump to the steering orbitrol, should be connected to
the
P
of the add-on open center part. Then connect a
line between
P1
of the manifold and the pressure line
of the orbitrol. Connect the
T
of the manifold to a tank
inlet (Figure 10 and Figure 11).
Connect the hoses leading from the orbitrol to
A1
and
B1
on the manifold. Connect the hoses to the steering
cylinders to
A
and
B
of the manifold (Figure 10 and
FIGURE 11 CONNECTIONS OF THE HYDRAULIC
OPEN CENTER MANIFOLD
FIGURE 9 ADD-ON PART OF THE OPEN CENTER
MANIFOLD
FIGURE 10 OPEN CENTER CONNECTION CIRCUIT