![background image](http://html.mh-extra.com/html/raven/autoboom-ultraglide-xt/autoboom-ultraglide-xt_installation-manual_788964042.webp)
C
HAPTER
4
38
Viper Pro Installation & Operation Manual
INSTALL THE SENSORS - ULTRAGLIDE NOT INSTALLED ON THE
MACHINE
INSTALL THE BOOM SENSORS
FIGURE 2. Mounted Boom Sensor
1. Locate the ultrasonic sensors (P/N 063-0130-026) in the UltraGlide XT installation kit.
2. Install the sensors on the 12” S-type sensor arms (P/N 063-0131-592) using two 1/4”-20 nylon insert lock nuts
(P/N 312-4000-057) and two 1/4” flat washers (P/N 313-2300-010) per sensor.
3. Mount the sensors to the front of the booms using two 1-9/16” W x 2-1/2” L x 3/8” thread U-bolts (P/N 107-
0171-611) and four 3/8”-16 zinc flanged lock nuts (P/N 312-1001-164).
NOTE:
The outer sensors should be mounted on the boom breakaway. The inner sensors should be
mounted just inside the inner fold joint.
4. Tighten the nuts to ensure the sensors are mounted securely.
Inner Sensor