![background image](http://html.mh-extra.com/html/raven/autoboom-ultraglide-xt/autoboom-ultraglide-xt_installation-manual_788964038.webp)
C
HAPTER
3
34
Viper Pro Installation & Operation Manual
FIGURE 21. Hydraulic Hoses Installed on Left Cylinder
7. Connect the other end of the installed hydraulic hose to the straight end of the installed tee fitting installed in
the base-end of the hydraulic cylinder.
8. Install the 90° end of the supplied hydraulic hose (P/N 214-1001-035) on the 90° end of the tee fitting.
FIGURE 22. Hydraulic Hose Installed
9. Connect the straight end of the installed hydraulic hose to the rod-end of the installed right hydraulic cylinder.
10. Ensure all hoses are secured away from moving parts and heat sources and do not interfere with boom
function.
-6 JIC M/M/F Swivel Run Tee
Adapter Fitting
(P/N 333-0012-043)
Hydraulic Hose
(P/N 214-1001-
035)
Hydraulic Hose
(P/N 214-1001-034)