176
ENGLISH
17.3.1 Control panel user menu
After pressing the key the following items will
appear in ascending order and it will be possible
to edit them:
DESCRIPTION
VALUES
Enable weekly
programmer
P on, P oFF
Auto/manual mode
setting
F Aut, F nor
Pellet type setting
From PL -5 to PL 5
Enable stand-by
function
S on, S oFF
Enable thermostat
infeed
t on, t oFF
After waiting 10 seconds from the last key to be
pressed, the display will go back to the main
page without saving any changes.
18 MAINTENANCE
18.1 SAFETY WARNINGS FOR
MAINTENANCE
Maintenance of the stove must be performed
at least once a year and should be planned in
advance with the Technical Assistance Service.
In some conditions, such as turning the stove
on and off or inappropriate use, the combustion
products can contain small soot particles that
build up in the smoke evacuation system. This
can reduce the cross-section of the smoke duct
and pose a fire risk. The smoke evacuation
system must be inspected and cleaned at least
once a year.
The maintenance operations must be carried out
when the stove is cold and with the electrical
power supply disconnected.
Before completing any maintenance operation,
adopt the following precautions:
• Make sure that the power supply plug is
disconnected.
• Make sure that all stove parts are cold.
• Make sure that the ashes are completely cold.
• Always operate with equipment that is
appropriate for maintenance.
• When maintenance is finished, re-install all
of the dis-assembled parts before restarting
operation.
The quality of the pellet, the stove operating
mode and combustion control can affect
maintenance activity frequency.
18.2 CLEANING
Perform the cleaning operations so as to
guarantee correct stove operation.
The table below lists the necessary cleaning
operations required for correct stove operation.
PARTS /
FREQUENCY
2 - 3
DAYS
30
DAYS
60/90
DAYS
Ash drawer
X
Glass
X
Combustion
chamber and
ash chute
X
Pellet tank
X
Air intake duct
X
It is recommended in the early periods of use of
the stove, or of a new type of pellet, to carry out
cleaning operations frequently, so as to be able
to assess the exact frequency of intervention.