175
ENGLISH
17.2 STATUS VIEWS
ICON
STATUS
DESCRIPTION
On
Valid connection to the Cloud service, with indication of signal
quality
Increasing animation
Wi-Fi connecting or invalid Wi-Fi parameters
Off
Wi-Fi parameters not entered
Off
Stove off
Switching on animation
Stove in switching on phase
Switching off animation
Stove in automatic switching off phase
Flashing
Stove in test phase or warm start request needs confirming
On
Stable flame and stove in work
On
Weekly programmer on and active
Flashing
Switching on/Switching off from weekly programmer
intervention
Quick flashing
Weekly programmer not set correctly
On
Tangential fan active on zone 1
On
Technical intervention requested due to expired scheduled
maintenance threshold
Flashing
Stove in test mode
Flashing
Stove in alarm (the relative alarm code will appear*)
On
Stand-by function enabled
Flashing
Powering on /Shutting down if stand-by active
Off
Stove off
On
Stove on
* See outlining table of possible anomalies
17.3 POSSIBLE OPERATIONS
The following operations are possible from the
home page:
ICON
PRESSURE
VIEW/SETTING
VALUES
Short
View current time
Long
Stove on/off (in normal operation and/or for restart after
a fault)
on, oFF
Long
Enter the user menu
See “User menu”
paragraph
Short
Desired zone 1 temperature setting using keys or
Default: 20 °C
Minimum: 0 °C
Maximum: 40 °C
Auto/manual mode setting (if thermostat active) using
keys or
F Aut, F nor
Short
Stove power setting using keys or
Default: P 100
Minimum: P 1
Maximum: P 100
Long
Start preload cycle (if stove on off, no alarms)
LoAd