28
0
525
-
M
0
1
5
-
1
RAV232 NL (VAR230/C4) - RAV234 NL (VAR230/C6) - RAV236 NL (VAR230/C8)
11
.
I
M
P
I
A
N
T
O
ELE
TTRI
C
O
Installazione da eseguire dallutilizzatore
11
11
.
WIRI
N
G
D
I
A
G
R
A
M
Power installations must be made by the user.
11
.
ELE
KTR
O
A
N
L
A
G
E
Netzanschluss durch Elektrofachkräfte
11
.
I
N
S
T
A
L
AC
IÓ
N
ELE
C
TRI
CA
Instalación que debe efectuar el utilizador
11
.
I
N
S
T
A
LL
A
TI
ON
ELE
C
TRIQU
E
Installation à effectuer par lutilisateur
11
.
1
I
M
P
I
A
N
T
O
ELE
TTRI
C
O
P
A
NN
ELL
O
C
4
11
.
1
WIRI
N
G
D
I
A
G
R
A
M
P
A
N
EL
C
4
11
.
1
ELE
KTRI
S
C
H
E
N
A
N
L
A
G
E
-
T
A
F
EL
C
4
11
.
1
I
N
S
T
A
LL
A
TI
ON
ELE
C
TRIQU
E
-
T
A
B
LE
A
U
C
4
11
.
1
I
N
S
T
A
L
AC
IÓ
N
ELE
C
TRI
CA
C
U
A
D
R
O
C
4
2
4
0
0
18
2
30
0
400
TR
OUT
0
1
2
3
4
5
6
7
8
9
PWR
SD
BA
T
RUN
ERR
SL
STOP
RUN
2
4V
0V
0
1
2
3
4
5
6
7
8
9
10
11
1
2
13
IN
NC
Q0
Q1
Q
2
Q3
Q4
Q5
Q6
Q7
Q8
Q9
V+
V+
V-
NC
COM
I0
I1
I
2
I3
I4
I5
I6
I7
I8
I9
I10
I11
I1
2
I13
DC IN
A
n
al
o
g IN
AI0
AI1
- + +
-
2
1
0
giall
o
/verde 1mmq
blu 0,5mmq
giall
o
/verde 1mmq
-
+
10
CNF0
7
65
KL
47
10
9
CNF4
9
CNF3
CNF
2
9
CNF1
15
CNF3
15
CNF
2
15
CNF
2
16
CNF4
16
CNF3
16
CNF
2
17
CNF4
17
CNF3
17
18
CNF4
18
CNF3
CNF
2
18
22
CNF4
22
CNF3
CNF
2
22
10
CNF4
10
CNF3
CNF
2
10
19
CNF4
19
CNF3
CNF
2
19
CNF0
15
CNF4
2
0
2
0
CNF
2
2
0
CNF3
O Ø
O 1
O 1
O
2
CNF0
6
CNF0
4
2
04
2
03
2
0
2
2
04
2
03
2
0
2
2
0
2
0
KL
143
54
51
6
2
51
58
58
143
70
69
19
10
10
10
10
10
PS
PD
22
K1
K
2
2
1
22
64
63
19
19
2
1
2
1
64
63
K1
K
2
2
3
2
3
2
7
2
6
2
5
2
4
10
2
6
2
5
2
4
19
2
4
15
15
15
10
2
5
161
61
6
2
6
171
71
7
2
7
18
18
18
14
2
143
144
47
L
2
47
61
9
2
93
94
19
C
PRD
1
2
4
FU4
FU5
9
2
93
94
DD
D
DDD
DDD
DDD
DD
D
D
blu 1mmq
marr
on
e 1mmq
14
CNF4
14
CNF3
CNF
2
14
144
143
14
2
143
144
10
19
10
19
19
1
2
3
4
5
6
7
8
BIANCO/BLU
BLU
CNF0
3
CNF0
2
BIANCO/BLU
BLU
SCHERMO
VITE CNF0
giall
o
/verde 1mmq
blu 0,5mmq
blu 0,5mmq
blu 0,5mmq
blu 0,5mmq
14
CNF1
141
CNF1
9
61
141
141
CNF1
5
CNF1
3
CNF1
1
CNF1
11
CNF4
CNF4
1
2
7
8
7
CNF
2
CNF
2
13
CNF4
SL
giall
o
/verde 6mmq
giall
o
/verde 1mmq
giall
o
/verde
2
.5mmq
n
er
o
2
.5mmq
n
er
o
1.5mmq
n
er
o
10mmq
r
o
ss
o
1mmq
r
o
ss
o
1mmq
L3
L
2
L1
FU0
11
1
2
11
11
1
2
8
8
8
8
8
8
66
66
66
7
2
71
71
59
60
45
K1
K
2
13
68
68
67
K3
KL
K3
K4
K4
K3
44
44
44
44
3
PEM
L1
13
13
13
13
13
13
13
KSF
FU3
CNF0
14
CNF0
11
8
CNF0
CNF4
CNF4
CNF3
CNF3
CNF
2
CNF
2
11
11
11
CNF3
CNF
2
CNF1
CNF3
1
2
CNF
2
1
2
CNF1
1
2
8
7
8
7
CNF4
CNF4
CNF3
CNF3
8
CNF1
CNF1
7
13
13
13
CNF
2
CNF3
CNF1
CNF3
CNF4
CNF
2
CNF4
CNF3
CNF
2
5
3
1
5
3
1
5
3
1
1
2
CNF0
10
9
CNF0
CNF0
R
2
S
2
T
2
R
2
FU
2
R1
S1
T1
KL
1
3
5
1
3
5
1
3
5
1
3
5
IG
KSF
11
9
2
F
S
RS
T
1
3
5
111
333
555
PD
O
2
D
46
14
2
144
CNF1
2
0
48
DD
50
A
4
3
2
1
SC
49
19
48
49
48
49
CNF1
19
CNF1
10
PS
144
CNF1
18
18
D
CNF1
17
17
D
2
3
CNF4
2
3
CNF3
CNF
2
2
3
CNF1
2
3
2
3
15
CNF4
15
D
CNF1
16
D
16
CNF1
22
2
1
CNF4
2
1
CNF3
CNF
2
2
1
CNF1
2
1
73
KL
CNF0
13
SL
CNF0
5
80
19
RC
R
E
F
.
D
E
NO
M
I
N
A
TI
ON
S
-
TERMINAL
TR
TRANSFORMER 200VA Vp 0/230/400 Vs 0/18 0/24
KL
LINE CONTACTOR
SL
KEY SWITCH ENAB. SINGLE POST OR SINGLE PAIR POST
SC
PAIR POST SELECTION SWITCH
RC
NOISE FILTER
KSF
PHASE SEQUENCE CONTROL RELAY
K3/4
EMERGENCY RELAY
K2
DOWN CONTROL RELAY
K1
UP CONTROL RELAY
PS
UP PUSH-BUTTON
PRD
RECTIFIER JUMPER
PLC
LOGIC PROGRAMMABLE CONTROLLER
PEM
EMERGENCY PUSH-BUTTON (MUSH-ROOM SHAPE)
PD
DOWN BUTTON
L2
BLOCK AND EMERGENCY RED WARNING LIGHT
L1
CORRECT PHASE SEQUENCE WHITE WARNING LIGHT
IG
MAIN INVERTER 1-0-2 (40A)
FU5
PROTECTION FUSE 24Vdc PLC 5x20 1A 250V QUICK
FU4
SECONDARY PROTECTION FUSES TR
(18V) 5x20 4A 250V QUICK
FU3
SECONDARY PROTECTION FUSES TR
(24V) 5x20 4A 250V QUICK
FU2
PRIMARY PROTECTION FUSES TR 10.3x38 2A 500V gl
FU0
TRIPLET OF MOTOR LINE FUSES 14x51 32A 500V aM
D
DIODE 1N 4003
CNF1/2/3/4FEMALE CONNECTOR TO SATELLITE POSTS
CNF0
CANNON 15-POLE FEMALE CONNECTOR, INTERCONNS.
C
ELECTROLYTIC CAPACITOR 4700 microF 50V
R
E
F
.
NO
M
E
N
C
L
A
TUR
A
-
MORSETTO
TR
TRASFORMATORE 200VA Vp 0/230/400 Vs 0/18 0/24
KL
CONTATTORE DI LINEA
SL
SELETT. A CHIAVE ABILIT. COM. SINGOLO E COPPIA
SC
COMMUTTATORE SELEZIONE COPPIE COLONNE
RC
FILTRO ANTIDISTURBO
KSF
RELE CONTROLLO SEQUENZA FASI
K3/4
RELE EMERGENZA
K2
RELE COMANDO DISCESA
K1
RELE COMANDO SALITA
PS
PULSANTE SALITA
PRD
PONTE RADDRIZZATORE
PLC
CONTROLLO LOGICO PROGRAMMABILE
PEM
PULSANTE EMERGENZA A FUNGO
PD
PULSANTE DISCESA
L2
SPIA ROSSA EMERGENZA E BLOCCO
L1
SPIA BIANCA SEQUENZA FASI CORRETTA
IG
INVERTITORE GENERALE 1-0-2 (40A)
FU5
FUS. PROTEZIONE 24Vdc PLC 5x20 1A 250V RAPIDO
FU4
FUSIBILE PROTEZIONE SECONDARIO
TR (18V) 5x20 4A 250V RAPIDO
FU3
FUSIBILE PROTEZIONE SECONDARIO
TR (24V) 5x20 4A 250V RAPIDO
FU2
FUS. PROTEZIONE PRIMARIO TR 10.3x38 2A 500V gl
FU0
TERNA FUS. PROT. LINEA 14x51 32A 500V aM
D
DIODO 1N 4003
CNF1/2/3/4CONNETTORE FEMMINA COLONNA SATELLITE
CNF0
CONNET. CANNON 15-POLI, INTERCONNS. CONSOLLE
C
CONDENSATOTE ELETTROLITICO 4700 microF 50V