PROBLEM
CAUSE
ACTION
Lift does not work
• main protection fuses broken
• replace
• Fusibili e trsformatore interrotto
• replace
• wiring system faulty
• check
Lift does not complete rise run
• motor heat probe disabled
• wait for reset
• load exceeding nominal capacity
• respect regulations (section 1)
• mains voltage too low
• check
Irregular lifting run
• air in hydraulic system
• operate some complete runs without load
• insuffi cient oil in tank
• top up oil (with lift at ground level)
Lift descends automatically then stops within
100 mm
• blocking valve dirty
• clean
• leak in one cylinder
• replace gaskets
Descent is extremely slow
• capacity regulation valve does not work
properly
• see “maintenance” section
Warning: with empty, unloaded, lift down motion is slow.
Motor runs as normal but rise speed is ex-
tremely slow
• descent valve partially open
• see “maintenance” section
• pump suction fi lter partially blocked
• clean fi lter
• worn or damaged pump
• replace pump
• calibration valve faulty
• contact technical services
Release cylinder failed to work.
• no air in system
• check
• release solenoid valve faulty
• see “maintenance” section
• release cylinder gasket worn or damaged • replace gasket
• compressed air tubes crushed or
damaged
• check tubing
8
Содержание RAV1110LK
Страница 16: ...16 0495 M002 0 3 RAV1110LK 2019 2496 98min 155max with spacer 2340 180 3064 603 1070 500 1070 500 2720 1450 500...
Страница 20: ...20 0495 M002 0 A 3...
Страница 24: ...24 0495 M002 0 P1 P2 400V50Hz3Ph 0 1 IG A B C 4...
Страница 34: ...34 0495 M002 0 2160 2340 A A Fig 10 Fig 11 Fig 12 M M M N E F E B 6...
Страница 36: ...36 0495 M002 0 Fig 16 Fig 17 6 F H L I G G Fig 13 Fig 15 Fig 14...
Страница 38: ...38 0495 M002 0 B D E F H G Fig 19 Fig 18 6 A C F G...
Страница 42: ...42 0495 M002 0 C Fig 22 Fig 23 6...
Страница 50: ...50 0495 M002 0 P1 P2 400V50Hz3Ph 0 1 IG A Fig 26 7...