Case 2:
Pin can be inserted into the metering opening and has more than 1 mm of play.
•
A new setting is required.
•
Remove pin from the metering opening.
•
Case 3:
Pin cannot be inserted into the metering opening.
•
A new setting is required.
•
Remove pin from the metering opening.
•
Continue with
11.5.1
Adjustment
u
Start the tractor/unit/transformer.
u
Versions K/D/C
Close the metering slide.
Set the stop to the maximally open position (end of the slotted hole).
u
Open the metering slide to the stop.
Version K: The spring is now released.
u
Switch the tractor off and remove the ignition key or switch the unit / transformer off.
11. Maintenance and service
MDS 8.2/14.2/18.2/20.2
5902916