19
6 Electrical connection
6.2
Power supply cable
ATTENTION!
In order to avoid hazards, the mains power
cable may only be replaced by the manufactu-
rer, its customer service representative or simi-
larly qualified personnel.
ATTENTION!
Non-functioning device !
Tighten mains lead cleat.
Connect a supply cable of at least Type H07RN-F
and tighten the mains lead cleat.
Connect the cable according to the following
diagram:
Gray connector terminals:
L1, L2, L3 (independent of rotary field).
Blue connector terminal:
Neutral conductor (neutral wire) (3NAC only).
Yellow-green connector terminals: Protective
conductors.
Содержание SelfCookingCenter XS UV
Страница 1: ...SelfCookingCenter XS UV and UV Plus CombiMaster Plus XS UV and UV Plus Original Installation Manual...
Страница 26: ...26 8 Wastewater connection 250 300 mm 10 12 max 1 m 3 ft 40 mm 1 min 3 5 min 3 5 40 mm 1...
Страница 30: ...30 10 Initial start up SCC CMP...
Страница 33: ...33 11 Maintenance Change HEPA filter...
Страница 39: ...39 15 Declaration of conformity 15Declaration of conformity...
Страница 40: ...80 02 467 V 13 2 04 2018 RTS Dja en...