29
10 Initial start-up
Self test
When first commissioning a new device, start a
one-time self-test. This test serves to adjust the
device to its specific ambient conditions.
It runs automatically, and takes 45 minutes; if an
UltraVent is in use, the test will take around 20
minutes longer.
> To perform the self-test, check the hook lad-
ders and the air baffle to ensure they are sea-
ted correctly.
>
The device must be connected to water,
wastewater, and electricity as per installation
instructions; gas devices must also be con-
nected to gas supply and exhaust lines.
>
The left side panel must be closed.
>
Insert a flat GN container into the middle of
the hook ladders, with the opening facing the
bottom.
> Do not open the cooking chamber door duri-
ng the self-test.