18
6 Electrical connection
CAUTION!
Improper installation can lead to personal inju-
ry or property damage!
Customer: provide accessible all-pole discon-
nect device with at least 3mm contact separa-
tion.
Remove the left side panel to access the connec-
tion port.
Removing the left side wall
> Remove the screws on the bottom of the side
panel.
> Pull the side panel down from the device.
> Remove the side panel.
Each device should have its own protected
power supply line.
Use a fixed connection to connect each device to
the power supply.
3NAC 400V only
Either a fixed connection or a plug connection
may be used to connect the device to the power
supply.
The units
are equipped with power cables (without plugs).
The cables are around 2.5 m in length.
.Cable connection point
The main fuse is behind the removable left side
panel inside the electrical compartment.