27
9 Ventilation, technical data, heat dissipation
9 Ventilation, technical data, heat dissipation
On-site ventilation:
When installing an exhaust hood, observe the
following:
> VDI Directive 2052 and local construction
authority regulations on exhaust hoods.
The exhaust hood should protrude 300-500
mm over the front of the device.
> Install the device underneath an exhaust hood
if using a VarioSmoker.
> Install a grease filter into the protruding part
of the exhaust hood.
Technical data
Noise emissions value: <70dBA
Water jet protection: IPX5
Thermal load [kJ/h]:
SCC
CMP
latent:
1.020
1110
sensible:
1.350
1420
We reserve the right to make technical developments / modifications.