- 49 -
V02 en, SCC_WE
Heating/Motor
Status
Values
Steam 50%
0 or 1
B5 = X°C
Start
Steam 100%
0 or 1
B5 = X°C
Start
Hot air 50%
0 or 1
B1 = X°C
Start
Hot air 100%
0 or 1
B1 = X°C
Start
Fan Motor top
Speed 1R Actual Speed X rpm
Start
Fan Motor top
Speed 1L Actual Speed X rpm
Start
Fan Motor top
Speed 3R Actual Speed X rpm
Start
Fan Motor top
Speed 3L Actual Speed X rpm
Start
Fan Motor bottom
Speed 1R Actual Speed X rpm
Start
Fan Motor bottom
Speed 1L Actual Speed X rpm
Start
Fan Motor bottom
Speed 3R Actual Speed X rpm
Start
Fan Motor bottom
Speed 3L Actual Speed X rpm
Start
Water/CleanJet
Status
Values
Solenoid valve filling Y1
0 or 1
Level electrode S2: water or low water
Start
SC Pump M4
0 or 1
Level electrode S2: water or low water
Start
Solenoid valve quenching Y2
0 or 1
B2 = X°C
Start
Solenoid valve moistening Y3
0 or 1
Start
Care valve Y4 + Pump M12
0 or 1
Level electrode S2: water or low water
Start
Cleanjet Pump M6
0 or 1
Start
Drain valve motor M7 direction1
0 or 1
End switch S12: 0 or 1
Start
Drain valve motor M7 direction2
0 or 1
End switch S12: 0 or 2
Start
Functional Group Test (open)
The following functional groups can be started: a sucessfull sequence will generate „OK“
Care
CleanJet
Steam generator management
Humidity control
Selftest
Components
Status
Loudspeaker T2
0 or 1
Start
Interior light
0 or 1
Start
Display test
Start
Ultravent
0 or 1
Start
Gas Burner
Status
Values
Gas steam blower Max
0 or 1
CO2: XX% Flame current: XX uA RPM:XXXX
Start
Gas steam blower Start
0 or 1
CO2: XX% Flame current: XX uA RPM:XXXX
Start
Gas steam blower Min
0 or 1
CO2: XX% Flame current: XX uA RPM:XXXX
Start
Gas hot air blower top Max
0 or 1
CO2: XX% Flame current: XX uA RPM:XXXX
Start
Gas hot air blower top Start
0 or 1
CO2: XX% Flame current: XX uA RPM:XXXX
Start
Gas hot air blower top Min
0 or 1
CO2: XX% Flame current: XX uA RPM:XXXX
Start
Gas hot air blower bottom Max
0 or 1
CO2: XX% Flame current: XX uA RPM:XXXX
Start
Gas hot air blower bottom Start
0 or 1
CO2: XX% Flame current: XX uA RPM:XXXX
Start
Gas hot air blower bottom Min
0 or 1
CO2: XX% Flame current: XX uA RPM:XXXX
Start