- 65 -
V02 en, SCC_WE
Format of HACCP Data
HACCP-Data are shown in the following format:
*** H A C C P ***
;
;
Ch-nr. >>210<<
= batch number
(number of stored cooking processes)
;
Type >>SCC_61<<
= unit type
;
Serial nr.>>E61SH11092534567<<
= Serial number of the unit
;
Version >>SCC - (s/o/C)<<
= Software version of the unit
(„C“ indicates, delay of CleanJet request is activated
Only chain units:
„s“ or „o“ shows unit ran on
(s) Supervisor- or (o) Operator mode.)
;
Time >>2011.09.20 12:27:26<<
= Starting date and time of the cooking process
;
Progr. >>Roast<<
= Program name
(manual mode was used, if „>><<“ appears )
;
#1 : Gartemp. / cabinet temp.
;
#2 : Kerntemp. Soll / core temp. target
;
#3 : Kerntemp / core temp.
;
#4 : Zeit (Std:Min:Sek) / time (h:min:sec)
;
#5 : Temp. Einheit / temp. unit
;
#6 : Energie Opt. / energy opt.
;
#7 : Energie 1/2 / energy 1/2
; #1 #2 #3 #4 #5 #6 #7
; Mode HOT AIR
000:00:00
= used cooking mode
29
-
32
000:00:00
C
-
-
; Mode COMBI
000:00:04
29
-
32
000:00:04
C
-
-
; Mode HOT AIR
000:00:07
29
-
32
000:00:07
C
-
-
29
-
32
000:00:11
C
-
-
;
end
=
End
of
cooking
process
B) Additional indications:
Progr. >>SCC - Universal Roast<<
= Indication of selected SCC process
Progr. >>SCC - ~ pork<<
= Copied SCC process with new name
Door opened or Door closed
= during cooking process
Start (power failed)
= Power failure longer than 15 minutes
end (HOME)
= Process terminated with Home key
end (RETURN)
= Process terminated with arrow back key
end (ERROR)
= Process terminated because of error
start ELC
= ELC Process started
restart (POWER)
= restart after switching off or power fail
end
= Process finished