V02 en, SCC_WE
- 20 -
Selftest
Selfttest
Your SCC will carry out an automatic
self test and adjust itself perfectly to
the set-up conditions and the altitude.
Selfttest
Your SCC will carry out an automatic
self test and adjust itself perfectly to
the set-up conditions and the altitude.
To determine the optimum number of
cleaner and rinse aid tablets, please specify
whether the unit is connected to normal
water or soft water. Please press the appro-
priate button
Unit is connected to soft water
(up to 8,75° e)
Unit is connected to normal water
(over 8,75° e)
Next
Selfttest
Your SCC will carry out an automatic
self test and adjust itself perfectly to
the set-up conditions and the altitude.
Softwater:
7°dH, 12,5°F, 8,7°E, 125ppm, 1,25 mmol/l
Self test
Note: Gas units: In case the unit was NOT delivered with the correct gas type configuration, it must be conver-
ted prior of starting the self test. Please refer to gas manual!
SCC_WE and CM_P units will run a automatic Self Test routine after installation.
This Self test will start under the condition, that the tempearture of B1,
B2 and B4 are below 40°C (104°F).
Additionally 1 flat and closed GN container (max 20mm) shall be inser
-
ted into the cabinet with the opening facing down at a height center to
the fan wheel. (201 - 202: 2 fan wheels = 2x GN containers)
The self test comprises a component test, calibration and determinati-
on of the boiling point
After the component test (S2, M4, Y1-Y4, CDS) the calibration will start
with the offset setting on P1 before the unit will determine the pressure
values for all fan speeds and directions in cold and dry condiition.
During step 200 the boiling point will be determined and stored.
This is followed by P1 calculating the pressure values for all fan speeds and
directions in steam and later combination mode 170°C (338°F).
Should at a later point in time the unit be reinstalled at a altitude more than 300m different to the original instal-
lation height, a new self test should be initialized in order to determine the new boiling point.
Such re-initialization can be be done in Basic settings, self test.
Calibration:
During a manual calibration only the P1 pressure values for cold (<40°C), steam (at boiling point) and combina-
tion (170°C) are calculated.
There will be NO determination of a new boiling point.
Selftest
step 200
Component test
Boiling point
calculation
Calibration