V08 en, SCC
- 70 -
Diagnostic - Gas Error History - Gas Reset
Whenever the unit is showing Gas reset, always check the gas error history. Indicated gas errors can can guide you
to faster troubl shooting
Note: be aware service errors and gas errors are different.
Gas errors are triggered by the ignition box itself.
Service 32 and Service 33 are a result of individual gas errors during operation of the gas unit.
Gas errors can be grouped into 2 sections
A)
Likely Ignition box failure
Gas error number
Action
1-15, 21, 23, 31 more than 5x:
change ignition box
33, 36, 37
and additional Service 32
change ignition box
B)
The following gas errors have most likely a reason in electrode distances, ignition wire or soiled burner head
(units 2004 - 2011):
Gas error number
Action
17, 18, 27, 28 for more than 5x
and additional Service 33
change only ignition box if the above components are ok.
19, 29 for more than 5x
and additional Service 33
Perform flue gas analysis, check ignition electrode distances, ignition wire and
burner. Clean Burner. If ok, change ignition box
20, 30
and additional Service 33
Check power supply 3 wire cable to gas blower for continuity (check TI 1426).
Change ignition box, if no result, re-install ignition box and change blower.
22, 32
and additional Service 33
check for gas supply and function of gas valve (22), check electrode distances,
ignition wire or soiled burner head
39, 42 for more than 5x
and additional Service 32
Check ignition electrode distances, ignition wire and burner. If ok, change igni-
tion box
34
L1 – N was changed
35
and additional Service 32
check voltage and frequency, only important when Service 32 was recorded
38
and additional Service 60
only important when Service 60 was recorded, contact Rational for software
repair.
After disassembling and reassembling of the burner always perform flue gas analysis.
When changing the steam burner always use a new white burner gasket:
Index E-G: 72.00.048, Index H-I: 72.00.077
The most common gas errors are:
19(Hot air), 29(Steam)
Ignition electrode distance, burner blocked from inside (units 2004-2011)
22(Hot air), 32(Steam)
no flame detection after ignition, check Gas main stop valve, Gas supply,
Gas pressure, Gas valve
When you have changed the ignition box, please always reset the Gas Error History!
Please reset the gas error history after changing the ignition box!
Содержание SelfCookingCenter SCC
Страница 1: ...V08 en SCC CMP 09 2018 Training Manual SelfCookingCenter SCC SCC_XS CombiMaster Plus CMP CM V08...
Страница 3: ...3 V08 en SCC...
Страница 10: ...V08 en SCC 10 Index E Index G Index H I Index I SCC XS...
Страница 25: ...25 V08 en SCC...
Страница 64: ...V08 en SCC 64 SCC Service level pwd TECLEVEL Process is active...
Страница 74: ...V08 en SCC 74...