- 81 -
V08 en, SCC
CM_P - Running times - rt
Description
Temp.-display Comment
Total S3 door openings
number
After changing individual component reset by
pressing
for 5 sec.
+
Total time Y1 valve filling
min
Total time Y2 valve quenching
min
Total time M4 SC-pump
min
Total time steam heating time
hrs
Total time hot air heating time
hrs
Total time steam mode
hrs
Can not be reset.
Total time hot air mode
hrs
Total time combination mode
hrs
Total time finishing mode
hrs
Total time cool down
hrs
Total running time unit
hrs
Emergency control humidity
hrs
Y5 humidity valve
number
After changing individual component reset by
pressing for 5 sec.
+
Total time drain valve
hrs
Total time cleanjet pump
hrs
Steam element time since last
reset of rt17, dP 31, dP32
After changing individual component reset by
pressing for 5 sec.
+
Only values up to 999 can be shown in the timer display. If the value exceeds 999 (e.g.1433) the first digit is
shown in the temp display as follows.
e. g. 1433: Temp. display
1
timer display 433