- 79 -
V08 en, SCC
CM_P - Error messages - Er
0, 1, 2
Ignition box
Ignition error
Ignition box defective
1 = top, 2 = bottom
0, 1, 2
Ignition box
Flame signal not recognized
Ignition box defective
1 = top, 2 = bottom
1, 2, 4, 8
Bus connection
Check power supply to motor / ignition box
LED must be on!
Bus connection
- 1 Motor top, - 2 Motor bottom
- 4 Ignition box top, 8 Ignition box bottom
UltraVent
Bus connection UltraVent not recognised, Bus con
-
nection defective or UV not connected to mains
supply.
Differential pressure sensor P1
Differential pressure sensor defective
(no signal), Cable to P1
Differential pressure sensor P1
Differential pressure sensor signal out of range,
check for plugged or loose hoses.
Mode switch
defective, change PCB
Temperature potentiometer
defective, change PCB
Timer / core probe potentiometer
defective, change potentiometer 40.00.464
No steam heating during CJ
No temperature raise above 60°C recognised by B1
Check SSR, steam element
real time clock CPU (rtc) not initial
-
ised
Set time and date for rtc
Battery voltage below 1,5V
change battery, Type CR 2032
(press timer key to delete error after repair)
Blink code Fan Motor top
see below
Blink code Fan Motor bottom
see below
Initialization of ignition box incor-
rect
Wrong rpm information for gas
blower
switch unit off and on again, change eeprom or run
EEPROM Repair program
PCB memory error (during self test) change PCB
Blink code Mo-
tor
Reason
Remedy
1x
Starting error
check if fan wheel is not blocked and can turn freely, change motor
2x, 4x, 7x, 10x
Motor defective
change motor
3x,
internal error
SCC_WE: flash software to 05.00.11.4 or higher, change motor
5x, 11x
Motor temperature
too high
Check fan wheel dimension, change motor
6x,
voltage error
check voltage supply, change motor
8x
only with 3-phase
motor
phase is missing
9x
communication error
check bus cable, apply contact grease (9003.0219) to bus cable plug
Blink code fan motor SCC_CMP
Содержание SelfCookingCenter SCC
Страница 1: ...V08 en SCC CMP 09 2018 Training Manual SelfCookingCenter SCC SCC_XS CombiMaster Plus CMP CM V08...
Страница 3: ...3 V08 en SCC...
Страница 10: ...V08 en SCC 10 Index E Index G Index H I Index I SCC XS...
Страница 25: ...25 V08 en SCC...
Страница 64: ...V08 en SCC 64 SCC Service level pwd TECLEVEL Process is active...
Страница 74: ...V08 en SCC 74...