- 41 -
V08 en, SCC
Changing PCB SCC
Software update to latest version
Reconnect unit to power supply and
switch unit ON
Insert SD card into new PCB
Removed SD card for usage in new
PCB.
Remove faulty PCB
Isolate unit from power supply
Changing pcb (pcb defective)
Only disconnect Software update
stick when basic SCC display is
shown.
All calibration and selftest data are located on both the PCB and the SD card Only the user
manual and the HACCP data are only on the PCB.
For this reason a software update must be done after changing the PCB.
Connect USB stick with latest
software to USB port.
Copy data from SD card to PCB
(press key 10 seconds)