Chapter 7: Operation - Administrator Functions
107
Channel Association Guidelines
This section describes the general concept for associating channels.
•
This function applies to both
Paragon II
Main and Stacking Units.
•
Channel ports of the same association group are all on the same
Paragon II Main Unit (either with or without any Stacking Units
connected).
•
Set the channel intended to activate other channels as the “first”
channel in the association setting.
•
Association of two or four channel ports is permitted for most Paragon
II models except P2-UMT242, which comes with two user ports only.
•
The sequence of associated channels can be random.
•
Each channel port belongs to one association group only.
•
Only channel ports connected to servers are available for association.
•
Up to 256 association groups are allowed per Paragon II system.
Limitations:
The Multiple Video function is not applicable to those channels which
share only one path via the tiered device, such as P2ZCIM,
P2CIM-APS2-B or P2CIM-AUSB-B (for IBM BladeCenter servers).
User Configuration
To view the current connection status for each user and to add, delete, and
edit user names and security rights, select option 2,
User Configuration,
from the Administration menu.