9
WIRING
WIRING
WARNING: Hazard of Shock and Fire
• Always use proper wire, wire connectors and fuse/
circuit breaker. See Specification Chart.
• Secure wire properly.
• Do not connect appliances to toilet circuit.
• Make sure power is off before proceeding.
• Use proper wire terminals for all wire connections.
Mounting controls:
Refer to instruction enclosed with control.
Install the Warning Label (L322) where it can be easily
seen.
5. Route wire from control per wiring diagrams.
Caution: To avoid kinking, do not pull on the
discharge hose. Be certain there is no pressure on
the discharge line.
Connect Hoses and wiring to toilet
Tip for Removing Intake Pump
Plug
Set screw must be loosened
with 1/8” hex key before
removing the intake pump
from motor
L442 1221jlc
2.
Select proper wire and fuse/circuit breaker size
from Specifications on Installation page.
3. Install fuse/circuit breaker in positive line at
source.
4.
Wire control to the toilet and battery using one
of the wiring diagram supplied with the Smart
Toilet Control.
1.
Determine proper wire size by measuring distance
from:
• Power Source to toilet and back to power source.
• Remote pump units - also include distance from power
source for remote pump and back to power source.
Same wire gauge must be used for both lower base and
remote pump.
PRESSURIZED FRESHWATER
VALVE
BLACK
BLUE
REMOTE INTAKE
PUMP
BLACK
(14AWG)
ORANGE/RED
(14AWG)
ORANGE
INTAKE
DISCHARGE
B
ATT +
B
ATT -
STC(H) SMART TOILET CONTROL
STC
RARITAN
DISC
H +
R
ED
WH
ITE
DISC
H - BL
A
C
K
SEN
SA
LEVEL
INLE
T+ B
LUE
INLE
T -
B
LACK
CO
MMO
N
FLO
AT
FRO
M MS
D
TO
MS
D
FUSE/
CIRCUIT BREAKER
BATTERY
SEE
RECOMMENDED
WIRE SIZE
ORANGE
BLUE
WHITE
WHITE
BLUE
BLUE
RED
RED
DISCHARGE PUMP
RED
RED
BLACK
BLACK
BLACK
INLET = NORMALLY OPEN
DISCHARGE = NORMALLY OPEN
WALL
SWI
TCH
PANEL
Содержание Marine Elegance 241E