background image

8

Connecting Remote Pump

Intake  pump  fittings  are  interchangeable  to  allow  more 

flexibility during installation. Inlet ports are located on either 

side of intake pump. Outlet port (to toilet bowl) is at top of 

intake pump (FIG 12).

NOTE:

  To avoid poor pump performance installation

of strainer (163000) is recommended

      1.    Slide fitting clips to open position (FIG 11).

      2.    Select inlet port to be used.

      3.     Install appropriate fittings into inlet and outlet ports.

NOTE

:  The 90° fitting can be rotated 360°.

      4.     Install the plug fitting into unused inlet port.

Discharge 

port

Inlet 

port

Discharge Lines

Raritan Sanitation Hose is recommended. Use part 

number SFH for 1 ½” hose or SFH1 for 1” hose

    

1.   Connect sanitation hose to discharge fitting on toilet.

NOTE: 

Discharge fitting is designed for 1” or 1½” 

hose. 1½” hose is secured at top of fitting and 1” is 

secured at the bottom. It is not necessary to remove 

the 1” barb if using 1½” hose. Use the fitting as is.

    2.   Run hose to appropriate device (e.g.: treatment            

system, holding tank, etc.).

NOTE: 

If installation requires routing through the

backwall rather than the floor, 90 degree kits are

available:

Use part# 221147 for 1½” hose or 221148 for 1” hose.

 

                   

              

Intake Lines

              Pressurized Freshwater Models

     

1.  Connect ½ (13mm) I.D. hose to pressurized  

 

 

   freshwater supply.

     2.  Install a shut off valve in intake line before water 

solenoid valve.

     3.  Connect hose from shut off valve to inlet port of 

water solenoid valve at the toilet.   

NOTE:

 To avoid malfunction of water solenoid due to 

debris in water, installation of Freshwater Strainer 

(190601) is recommended.

FIG 10

FIG 11

FIG 13

Open

Arrow

Plug

Inlet Ports

Outlet Port

To Bowl

FIG 8

5. 

Slide fitting clips back to closed position (FIG 11)

6.    Connect hose from seacock to inlet port of intake 

pump. If used, strainer is in-line. Use hose clamp 

provided.        

IMPORTANT:  Double clamp all below waterline 

hose connections!

7. 

Connect hose from outlet port of intake pump to 

bowl elbow located on back of toilet bowl.

 

           

Mounting Remote Pump

   

 1.   Remote pump uses ¾” (19mm) ID hose for connec

-

tion. 

    2.   Locate  remote pump between thru hull fitting and 

toilet bowl.

    3.   Locate in an area away from berth to keep noise 

level down.

    4.   Use Inline Strainer (optional) to avoid clogs.

    5.   Secure remote pump to the floor  using four bolts 

through the pump base (FIG 13).

Closed

IMPORTANT:  Be sure not to install plug fitting into 

outlet port!  Damage to pump will occur!

PLUMBING

 

L442  1221jlc                                                                                                             

FIG 12

Содержание Marine Elegance 241E

Страница 1: ...improper installation or operation of this product WARNING HAZARD OF SHOCK OR FIRE Always use recommended fuse circuit breaker and wire size Motors used with this product are Ignition Protected They a...

Страница 2: ...In Line Strainer if you have one No special toilet paper is required Water should appear in the bowl within ten seconds If not see troubleshooting section Hard objects or stringy substances paper tow...

Страница 3: ...8 mm I D discharge hose approximately 3 feet 1 m long Two buckets Nontoxic antifreeze approximately 1 quart 1 liter Steps 1 Close the intake and discharge seacocks 2 Turn off power to unit 3 Disconnec...

Страница 4: ...tings 5 For 120 240 VAC units use 12VDC specifications from transformer to unit Maximum suction of Intake Pump Maximum height above waterline 4 ft 1 2m from Intake Pump Maximum height of discharge ven...

Страница 5: ...n guide with labels Additional Parts included with sea water model 1 Remote pump assy 2 Relay for remote pump SeaFresh models only Additional Parts Required MOUNTING Mounting Toilet Mounting surface m...

Страница 6: ...NMENT LINES FIG 3 FIG 4 FIG 5 FIG 6 2 Place Mounting Template on deck against the wall with arrow located on center mark and secure with tape FIG 3 3 Drill holes for floor mounting brackets at locatio...

Страница 7: ...Valve Waterline remote pump Electroscan Waterline Discharge Seacock Waterline Discharge Vented Loop Intake Vented Loop Discharge Seacock Intake Seacock Electroscan Pressurized Freshwater Model Install...

Страница 8: ...its are available Use part 221147 for 1 hose or 221148 for 1 hose Intake Lines Pressurized Freshwater Models 1 Connect 13mm I D hose to pressurized freshwater supply 2 Install a shut off valve in inta...

Страница 9: ...and fuse circuit breaker size from Specifications on Installation page 3 Install fuse circuit breaker in positive line at source 4 Wire control to the toilet and battery using one of the wiring diagr...

Страница 10: ...4 10 Washer SS Flat 4 50 PLA26 Elbow Adapter 3 4 X 1 2 PARTS NOT SHOWN 221175 L Bolt 2 221170A Discharge Hose Support Strap F188 Well Nut 10 32 3 F144 Washer 10L 18 8 SS 2 MOUNTING BRACKET ASSEMBLY 22...

Страница 11: ...11 EXPLODED PARTS L442 1221jlc...

Страница 12: ...except as specifically set forth in this warranty 6 This warranty gives you specific legal rights and you may also have other rights which vary from state to state LIMITED WARRANTY 530 Orange Street...

Отзывы: