8
Connecting Remote Pump
Intake pump fittings are interchangeable to allow more
flexibility during installation. Inlet ports are located on either
side of intake pump. Outlet port (to toilet bowl) is at top of
intake pump (FIG 12).
NOTE:
To avoid poor pump performance installation
of strainer (163000) is recommended
1. Slide fitting clips to open position (FIG 11).
2. Select inlet port to be used.
3. Install appropriate fittings into inlet and outlet ports.
NOTE
: The 90° fitting can be rotated 360°.
4. Install the plug fitting into unused inlet port.
Discharge
port
Inlet
port
Discharge Lines
Raritan Sanitation Hose is recommended. Use part
number SFH for 1 ½” hose or SFH1 for 1” hose
1. Connect sanitation hose to discharge fitting on toilet.
NOTE:
Discharge fitting is designed for 1” or 1½”
hose. 1½” hose is secured at top of fitting and 1” is
secured at the bottom. It is not necessary to remove
the 1” barb if using 1½” hose. Use the fitting as is.
2. Run hose to appropriate device (e.g.: treatment
system, holding tank, etc.).
NOTE:
If installation requires routing through the
backwall rather than the floor, 90 degree kits are
available:
Use part# 221147 for 1½” hose or 221148 for 1” hose.
Intake Lines
Pressurized Freshwater Models
1. Connect ½ (13mm) I.D. hose to pressurized
freshwater supply.
2. Install a shut off valve in intake line before water
solenoid valve.
3. Connect hose from shut off valve to inlet port of
water solenoid valve at the toilet.
NOTE:
To avoid malfunction of water solenoid due to
debris in water, installation of Freshwater Strainer
(190601) is recommended.
FIG 10
FIG 11
FIG 13
Open
Arrow
Plug
Inlet Ports
Outlet Port
To Bowl
FIG 8
5.
Slide fitting clips back to closed position (FIG 11)
6. Connect hose from seacock to inlet port of intake
pump. If used, strainer is in-line. Use hose clamp
provided.
IMPORTANT: Double clamp all below waterline
hose connections!
7.
Connect hose from outlet port of intake pump to
bowl elbow located on back of toilet bowl.
Mounting Remote Pump
1. Remote pump uses ¾” (19mm) ID hose for connec
-
tion.
2. Locate remote pump between thru hull fitting and
toilet bowl.
3. Locate in an area away from berth to keep noise
level down.
4. Use Inline Strainer (optional) to avoid clogs.
5. Secure remote pump to the floor using four bolts
through the pump base (FIG 13).
Closed
IMPORTANT: Be sure not to install plug fitting into
outlet port! Damage to pump will occur!
PLUMBING
L442 1221jlc
FIG 12
Содержание Marine Elegance 241E
Страница 11: ...11 EXPLODED PARTS L442 1221jlc...