bend (136002) has a set out of 1

50

to 

1

65

mm and is available for purchase separately.

DO NOT BED THE PAN IN PLACE 

USING

Installation Instructions

 

 

 

203147

 

/

 

203148

 

Edg

II

 

Rim

le

ss

 Wall 

F

a

c

e

d

 To

i

le

t

 S

uit

w/

 Sl

im

 or ST

D

 Sea

t

Important Information

This Product is to be installed by a licensed plumber, installation must comply with AS/NZS 3500 and relevant plumbing codes. 

Isolating stop taps are recommended to be fitted to the hot and cold inlet connections. Please leave this document with the Product 

after installation.

 

Please ensure that the lines are flushed prior to installation as contaminates in the water can damage 

O

-rings and 

valves

 

and will 

affect the performance of the Product. 

Before installation, remove Product from packaging and check the Product matches what you have ordered, is complete with all parts 

(per exploded drawing) and is not damaged. 

If the Product is incorrect, damaged or missing parts DO NOT install 

and return to store 

with proof of purchase for a refund or replacement.  Installed Products are warranted for genuine manufacturing defects arising in your 

Product during the course of normal domestic or 

equivalent 

commercial use for the term of the warranty period. Our manufacturer's 

warranty does not cover Product which are incorrect or have been installed with pre-existing damage or missing parts.

Pressure & Temperatures

- Maximum Hydrostatic Pressure - 500kPa. (per AS/NZS3500.1 (Clause 3.3.4) which states "The maximum static pressure at any outlet,

other than a fire service outlet, within a building shall not exceed 500kPa." 

NB

. Pressures above 500kPa can cause damage from water

hammer, reduced life of appliances, taps and fittings, and cause excessive noise in the system.

- Minimum Hydrostatic Pressure - 100kPa. This Product may not be suitable for use with a gravity fed water supply or with continuous

flow or instantaneous hot water systems.

- Maximum operating temperature - 65°c.

Revision Date: 

25

 Nov 2021

 

Revision Number: 

1

.0

 

I

ssue Date: 

25 Nov 2021

Optional 

Set Out

Set Out Drawing

Installation Instructions

 - Page 1

1.

Pan Installation

 - m

ark the centre line of the pan connector on the floor for 'S' trap installation or on the wall for 'P' trap installation.

2. Place the pan into position, centralising the pan with your centre line, then draw around the pan base and mark the entry points on

the floor to where the floor fixing holes are located on the side of the pan.

3. Remove the pan and drill and screw the floor fixing brackets into place. Set the floor fixing brackets 20mm inside the line drawn

around the base of the pan. Use suitable floor fixing screws / anchors to suit the floor material. 

NB

. The pan must be on a level surface

that is square with the wall. If the floor slopes away, the pan will need to be levelled using suitable floor chocks around the pan which

 

 

will support and stabilise the pan. The standard variance bend (133601) supplied has a set out of 

9

0

 to 1

0

5

mm. The optional variance

 

 

CEMENT, CONCRETE OR SIMILAR MATERIAL

.

4

a

'S' trap installation

 - place the variance bend into the floor outlet, from the floor to the centre of the pan outlet is 185mm, ensure the 

variance bend is straight and square to the wall, assemble the variance bend wall brace and fix to the finished wall. Measure the 

distance from the back edge of the pan to the start of the 'P' trap and add on sufficient length for the variance bend collar to fully

 

engage the 'P' trap. Remove the locking ring and rubber boot from the variance bend. Measure out from the finished wall to the 

measurement you have predetermined and cut the excess off the variance bend. The distance between each ridge on the variance 

bend is 10mm. Once the excess has been cut off the variance bend reas

s

emble the rubber boot and locking ring.

 Use the supplied 

variance bend wall bracket, with appropriate screws or anchors for the wall material, to fix the variance bend to the wall and to reduce 

the risk of misalignment.

 

5.

Slide the pan into place, being careful that full engagement of the pan 'P' trap and variance bend has been achieved

.

NB

. pre-soaping the rubber boot on the variance bend will assist with easier engagement onto the pan 'P' trap.

6.

Once the pan is in place and connected to the variance bend, screw the pan in place using the supplied fixing screws and cover.

 

DO

NOT OVER TIGHTEN SCREWS AS THIS MAY CAUSE THE PAN TO CRACK

Run a bead of plumbing grade silicone around the pan and

up the edge of the wall to finish off.

7.

'P' trap installation 

- The distance from the back edge of the pan to the start of the 'P' trap is 

130

mm (due to shrinkage variations

please measure the distance on the pan to confirm} taking into account full engagement of the pan collar on the 'P' trap. Install waste

pipe as per Australian standards and local authority requirements. The distance from the floor to the centre of the 'P' trap is 185mm, set

your waste pipe height accordingly.

 

DO NOT USE OFFSET PAN COLLARS ON 'S' OR 'P' TRAP INSTALLATIONS AS THIS WILL

COMPROMISE WASTE DISCHARGE.

Contact Details

Tradelink Pty Ltd

ABN:29000003832 

Raymor Customer Care 

Ph: 1800 729 667

1051 Nudgee Road Banyo QLD 4014 

[email protected]

NB

. These installation instructions are to be used in conjunction with the Byron Inwall Cistern installation instructions.