PLUMBING
PLUMBING
WARNING: HAZARD OF FLOODING
Toilets mounted at or below the waterline, at greatest
angle of heel, and connected to a Seacock/Thru Hull
Fitting(s) MUST have VENTED LOOPS installed in
toilet discharge plumbing and between raw water
intake pump and toilet bowl.
Install vented loops per manufacturer’s instructions.
Sea Water Models installed below the waterline
MUST have a vented loop installed between the intake
pump and the toilet bowl.
Double clamp all below-waterline connections.
IMPORTANT
• Fittings and 90° bends should be kept to a
minimum.
• In-Line Strainer may be installed on Sea Water
Models per Installation Instructions. This will
prevent clogs.
• Discharging untreated sewage is forbidden in all
U. S. waters within the three-mile limit.
• Thru-hull fittings and seacocks must be installed
where they are easily accessible.
• Use only quality reinforced hoses such as Raritan
Saniflex (SFH)
• Secure all hoses properly.
Waterline
Pressurized Freshwater Model Installed
Above/below Waterline
Discharge
Pressurized Fresh-
water
Source
Shut off Valve
Waterline
remote pump
Electroscan
Waterline
Discharge Seacock
Waterline
Discharge Vented
Loop
Intake Vented Loop
Discharge
Seacock
Intake Seacock
Electroscan
Pressurized Freshwater Model Installed
below Waterline
Holding Tank
Residual Water in the Bowl
The Marine Elegance is equipped with an integral
vent to maintain water in the bowl when the plumb-
ing lines are routed downward (See FIG 8a and FIG
8b). The Smart Toilet Control (STC) is designed to
add water at the end of the flush cycle. The toilet
will not hold more than about 4” in the bowl. If any
of the discharge hose runs higher than the internal
integral vent, DO NOT REMOVE THE VENT CAP.
For vent to work properly in downward installa-
tion, the vent cap must be removed (see FIG 9).
Remote Intake Pump Model Mounted
below Waterline
Toilet Installed above waterline
or above Treatment Device and
or Holding Tank = Downward
discharge flow
Remove vent cap
Toilet installed below waterline
or below Treatment Device
and or holding Tank = Upward
discharge flow
Do not remove vent cap
FIG 7a
FIG 8a
FIG 9
Vent Cap
FIG 7b
FIG 7c
FIG 8b
To enable Integral Vent, remove Vent Cap (FIG 9),
connect ¼ hose and connect hose to a deck vent fitting
(Reference FIG 7C). Hose and deck fitting not
included.
L442 1221jlc