DElIvERED ITEMs
Carefully remove the welding unit from its packaging and check that you have the following items:
•
Welding unit
•
Welding cable
•
USB flash memory drive
•
Bar code pen reader
When parts are missing or damaged, please contact your dealer.
This welding unit is Class 1 and requires an earthed (grounded) connection. An earth spike must be used with generators.
This unit is supplied in either 110 volt or 230 volt operation. Check the rating plate on the side of the unit for the correct supply voltage.
The power source must be capable of providing 3500 Watts.
ElECTRICAl sAFETY
Extension cables should only be used if they comply with the HO7RNF harmonized standard. They must be fitted with connectors to the BS EN
60309-2 standard. All cables must be unwound from the reel to stop inductive heating effects. The cable dimensions should be as follows:
110 Volt operation
230 Volt operations
Up to 63mm diameter
Up to 63mm diameter
2.5mm2 cable = 30m
1.5mm2 cable = 40m
Up to 180mm diameter
Up to 180mm diameter
2.5mm2 cable = 20m
1.5mm2 cable = 25m
Over 180mm diameter
Over 180mm diameter
4.0mm2 cable = l0m
2.5mm2 cable = 20m
It is recommended for increased electrical safety to use a Residual Current Device (RCD) with a tripping current of not more than 30 mA.
Always check your RCD every time you use it.
The supply cable must be inspected for signs of damage before each use and the equipment may only be used if in perfect condition.
Damaged cables must be replaced by an approved service agent.
This equipment is classified as “Portable for use on industrial applications”, and must undergo a formal electrical safety check (Portable
Appliance Test) as per local regulations.
WARnIng! switch off and remove the plug from the mains before adjusting,
cleaning or if the cable is cut, damaged or entangled.