30: Bar Code Mode: No fitting connected
This fault is shown if the output lead is not connected to a fitting when a bar code is read. Connect the fitting.
31: Bar Code Mode: Ohms error
This fault is shown if the connected fitting resistance is different from that coded into the bar code. Try another fitting.
40: Bar Code Invalid: Temperature Compensation.
Digits 22 and 23 of the bar code have been decoded incorrectly.
41: Bar Code Invalid: Resistance Coefficient.
Digit 18 of the bar code has been decoded incorrectly.
42: Bar Code Invalid: Welding Voltage.
Digits 13 and 14 of the bar code have been decoded incorrectly.
43: Bar Code Invalid: Regulation Mode.
Digit 12 of the bar code has been decoded incorrectly.
44: Bar Code Invalid: Fitting Size.
Digits 9, 10 and 11 of the bar code have been decoded incorrectly.
45: Bar Code Invalid: Cooling Time.
Digit 7 of the bar code has been decoded incorrectly.
46: Bar Code Invalid: Fusion Cycle Type.
Digit 5 of the bar code has been decoded incorrectly.
47: Bar Code Invalid: Energy Correction.
Digit 3 of the bar code has been decoded incorrectly.
48: Bar Code Invalid: Component Type.
Digits 1 and 2 of the bar code have been decoded incorrectly.
49: Bar Code Invalid: Check Digit.
Digit 24 of the bar code has been decoded incorrectly.
50. USB Memory: Disc full.
This fault will happen if the USB flash memory pen is full. Delete some from the device.
51: USB Memory: File allocation table full.
This will happen if the USB flash memory pen’s file structure becomes fragmented. Follow the instructions with Windows to
de-fragment the memory pen.
52: USB Memory: File not found.
When performing a software upgrade, the required file was not found on the memory drive. Reload the upgrade files onto the
memory drive.
127: Power off failure.
If the power is turned off while the unit is welding, this fault will be recorded to the data log.
MAInTEnAnCE
Regularly check for obvious defects such as loose or damaged cables and connectors. Look for worn components and broken covers or
housings.
There are no user serviceable parts inside the unit It should be returned to an approved service agent for repair and calibration.
It is recommended that the unit is calibrated every twelve months. After use, clean the outside of the unit with a soft brush or cloth. Carefully
wind up and store the cables around the frame in the location provided.
DIsPOsAl
The equipment and packaging should be sorted for environmentally friendly recycling.
DO NOT DISPOSE OF THIS EQUIPMENT INTO HOUSEHOLD WASTE I
According to the European Directive 2002/96/EC Waste Electrical and Electronic Equipment (WEEE), when no longer suitable for use, this
equipment must be separately collected and sent for recycling.
12