09/11/2018
RANS S-21 OUTBOUND
TEXT MANUAL
54
ELEVATOR BALANCING
•
Elevator balancing must be performed on a flat work surface.
•
Elevator and Trim Tab must be final painted.
•
Trim Tab must be installed onto Elevator.
•
Servo with Push Rod must be installed in Elevator and connected to Trim Tab.
•
Trim Servo Cover with screws must be installed.
WARNING!
LEAD POISONING HAZARD
This aircraft contains Inorganic Lead which is for industrial and commercial use
only. Misuse of this product will present a health hazard. Dust or fume created
from handling or processing this product may be harmful if inhaled or swallowed.
Chronic overexposure to dust and/or fumes may result in severe damage to blood
forming, nervous, urinary, and reproductive systems.
Precautions:
•
Do
NOT
eat, drink, use tobacco products, or apply cosmetics in work areas.
•
Wash / shower thoroughly after handling and before eating, drinking, or using
tobacco products.
•
Dispose of water in compliance with Federal, State, and Local Regulations.
•
Do
NOT
reuse empty containers.
•
Avoid Dust / Fume Inhalation, swallowing of dust and contact with skin and eyes.
•
Keep containers and material free of moisture
CAUTION:
Wear rubber gloves and a particle mask when working with Lead.
Lead is a heavy metal and is dangerous for your health. Take care when working
with Lead to clean up all shavings and to store Lead products out of reach of
children.
The elevator will be balanced by using a lead/epoxy mix placed in the leading
part of the elevator tips. This section is sealed by the balance rib and accessed
b
y the builder located 1/2” hole in the elevator tip skin.
1.
Place the elevator upside down.
2.
Place a bolt in the hinges of the elevator.