9
PROBLEM
REASONS
ACTION
Unit indicator doesn’t light
- No power
- Master Control is not working
- Fuse is burnt
- Panel is not working
- Check the circuit
- Change master control board
- Change the fuse - (Size: 250V-15Amps)
- Change the panel
Unit is not working
- Interfered by power
- Interfered by environment
- Panel is not working
- Power off
- Remove or keep away from interference
- Change the panel
Display is normal but without
wind or the wind speed is
too low
- The fan gets stuck
- Water screen or dust-net is blocked
- Fan is distorted
- Master control board not working
- Check the fan
- Clean/change water screen or dust-net
- Change fan
- Change master control board
Motor is not working
- Master control is not working
- Panel is not working
- Change master control board
- Change the panel
The drain valve leaks
water
- The drain valve is loose
- Screw tightly
Fan is not working
- The blade and the surrounding locks
- Motor is burnt
- Master Control is not working
- Check the fan and the surroundings
- Change the motor
- Change the master control
The diffuser doesn’t work
- The small motor is burnt
- The crankshaft is broken
- The crankshaft breaks off the
swing rails
- Change the motor
- Change the crankshaft
- Return the position again
The fan spouts water
- The water pipe falls off
- Check the water pipe
Remote Control is not
working
- Battery is old
- Something is blocking the receiver
- Replace the battery - CR2025/3V
- Clear blockage