background image

5

INTRODUCTION

The CB-30L Cool Boss evaporative air cooler by Ranger 

Products™ provides a low-cost, environmentaly 

friendly way to keep shops cool and workplace 

areas comfortable even during the hottest summer 

months. The CB-30L uses ordinary tap water  

combined with forced air to reduce air  

temperatures by as much as 26ºF.

The CB-30L Evaporative Air Cooler is a high-tech  

product from Ranger. Its basic principle are as follows: 

water evaporation drives away the surrounding heat and 

causes the temperature to cool down. 

Its working principle is that negative pressure occurs 

because of wind draining by exhaust fan: air goes 

through congruent cooling pad and the motor pump 

continuously transport water to the pipes and cooling pad 

at the same time.

The water continuously wetting the cooling pad surface 

evenly and the wet cooling pad angle makes the water 

current flow to the side of wind inlet, absorbing a certain 

amount of heat from the air, which cools down upon  

contact with the cooling pad. 

The wet cooling pad also makes the wind cool and fresh. 

The circulating water falls to the bottom, forming the  

water cycle. There is a water level indicator at the panel. 

So, when the water level indicator reaches the bottom 

level, the inlet valve will open automatically to add water. 

When the water reaches the indicated full level, the valve 

will close automatically.

FEATURES

The CB-30L features a micro-computer programmed 

control panel with LCD display and comes with a  

convenient remote control. Built-in timer allow the unit to 

be programmed to turn on or off at preselected times. 

A large 30-inch diameter fan operates all three selectable 

speeds and a thick cooling pad ensures even water  

distribution and reliable heat absorption.  

 

Automatic swing-louvers move side to side and help  

circulate cold air more efficiently providing a larger 

 

cooling area than traditional evaporative air coolers. Four 

rubber casters with brakes allow easy mobility.

This unit has these added advantages and other special 

features:

1.  Specially designed powerful blade and water-proof fan 

motor.

2.  A thicker and bigger cooling pad for better heat  

absorption.

3.  Multi-layered congruent wave and fiber cooling pad 

makes the water cold.

4. A rigid construction.

SET UP AND OPERATION

1.  

DO NOT RUN PUMP DRY

 or severe pump damage or 

failure will result.

2.  Use only in a ventilated open environment with fresh 

air supply.

3. Area must be free from airborne pollutants, flammable 

gasses and contaminants.

4.  Ambient operating temperature must remain between 

65-113ºF (18-45ºC).

5.  Maximum water temperature should never exceed 

113ºF (45ºC).

6.  Electric voltage must not exceed 115V +/- voltage.

7. 

 NEVER

 spray unit with water as moisture may harm 

motor and other electrical system components.

8. Before performing any type of service or cleaning, turn 

cooler unit to 

OFF 

setting then disconnect unit from the 

electrical power source.

CONSUMER NOTICE:

 This product contains chemicals 

which are known to the state of California to cause 

cancer, birth defects or other reproductive harm.

Содержание CB-30L

Страница 1: ...pment must be made by the purchaser against the transportation company at the time shipment is received BE SAFE Ranger Evaporative Air Coolers are designed and built with safety in mind However proper...

Страница 2: ...on to return merchandise has been received For all merchandise returned to BendPak Ranger for reasons other than warranty a 20 restocking fee and round trip shipping costs will be deducted from the cr...

Страница 3: ...amaged loose or missing parts Any CB 30L air cooler that appears to be damaged in any way is found to be worn or operated abnormally must be removed from service immediately Any CB 30L evaporative air...

Страница 4: ...mmable liquids or gases 14 Ensure cooler pumps are running continuously to saturate and wet media pads at all times during operation 15 ALWAYS maintain a distance of at least 50 feet from any open fla...

Страница 5: ...mmed control panel with LCD display and comes with a convenient remote control Built in timer allow the unit to be programmed to turn on or off at preselected times A large 30 inch diameter fan operat...

Страница 6: ...Pipe Size inch NPT fitting Back Safety Net Water Distributor Water Pipe Grille Motor Cooler Housing LCD Panel Side Panel Front Net Add Water Back Caster Front Caster Footing Water Tank Diffuser CB 30...

Страница 7: ...e function of setting time Press TIMER 6 Press SWING to move the louvers side to side and help circulate cold air more efficiently 7 ION button Built in ionizer to release negative ions for cleaner ai...

Страница 8: ...e must not exceed the required volt 5 No pollution around the working area B The circuit of the machine must be properly connected and protected to prevent mouse bites Trampled or over stretched which...

Страница 9: ...et Change fan Change master control board Motor is not working Master control is not working Panel is not working Change master control board Change the panel The drain valve leaks water The drain val...

Страница 10: ...y Relay Marboard Signal Switch Capacitors Red Orange White Live Wire AC L Ground Neutral Wire AC N Max Airflow 10595 CFM Power Consumption 550W Style Axial Water Consumption 2 65 3 96 Gal Hr Water Cap...

Страница 11: ...________________________________ ____________________________________________________________________ ____________________________________________________________________ _____________________________...

Страница 12: ...12...