Network operation and remote control
R&S
®
AREG800A
192
User Manual 1179.3615.02 ─ 01
Table 10-5: Meaning of the bits used in the questionable status register
Bit No.
Meaning
0–15
Not used
10.4.6
Operation status register (STATus:OPERation)
This condition part contains information on the actions currently being performed by
the instrument, while the event part contains information on the actions performed by
the instrument since the last readout of the register.
To read the register, use the query commands
or
.
Table 10-6: Meaning of the bits used in the operation status register
Bit No.
Meaning
0
Calibrating
The bit is set during the calibration phase.
1–2
Not used
3
4–15
Not used
10.4.7
Application of the status reporting system
The purpose of the status reporting system is to monitor the status of one or several
devices in a measuring system. To do this and react appropriately, the controller must
receive and evaluate the information of all devices. The following standard methods
are used:
●
Service request
(SRQ) initiated by the instrument
●
Serial poll
of all devices in the bus system, initiated by the controller to find out
who sent an SRQ and why
●
Query of a
specific instrument status
by commands
●
Query of the
error queue
10.4.7.1
Service request
Under certain circumstances, the instrument can send a service request (SRQ) to the
controller. Usually this service request initiates an interrupt at the controller, to which
the control program can react appropriately. An SRQ is always initiated if one or sev-
eral of bits 2, 4 or 5 of the status byte are set and enabled in the SRE. Each of these
bits combines the information of the error queue or the output buffer. To use the possi-
bilities of the service request effectively, all bits should be set to "1" in the enable regis-
ters SRE and ESE.
Status reporting system
Содержание AREG800A
Страница 1: ...R S AREG800A Automotive Radar Echo Generator User Manual 1179361502 Version 01 T 2...
Страница 53: ...Required options R S AREG800A 53 User Manual 1179 3615 02 01 For more information see data sheet...
Страница 401: ...List of commands R S AREG800A 401 User Manual 1179 3615 02 01 RST 249 SAV 250 SRE 250 STB 250 TRG 250 TST 251 WAI 251...