Raisecom Technology Co., Ltd
15
1
st
2
nd
Definition
ON ON Long Haul -36dB
(
factory default
)
OFF
ON
Long Haul -43dB
ON
OFF
Short Haul -15dB
OFF OFF Gain
Mode
Long Haul -36dB
:
Equalizer detects the input wave and compensates 36dB at most to adjust
input E1 signal, and this function is used for cable loss (frequency), but not flat
loss (resistive)
;
Long Haul -43dB
:
Equalizer detects the input wave and compensates 43dB at most to adjust
input E1 signal, and this function is used for cable loss (frequency), but not flat
loss (resistive)
;
Short Haul -15dB
:
Equalizer detects the input wave and compensates 15dB at most to adjust
input E1 signal, and this function is used for cable loss (frequency), but not flat
loss (resistive)
;
Gain Mode
:
Equalizer detects the input wave and compensates 29dB at most to adjust
input E1 signal, and this function is used for flat loss (resistive), cable loss
(frequency).
The relationship between hardware configuration DIP-switches and software
configuration
The relationship is in following table:
Hardware switch
Whether software can
configure
SW1~SW4 Yes
SW5 Yes
SW6 No
Basic connection topology
The following topologies are just for reference, and users can organize your
network according practice. The following topologies are RC903-V35FE1
examples.
z
Point-to-point “master-slave clock” mode