iTN2100 (P100R002) Hardware Description
Chassis
Raisecom Technology Co., Ltd.
6
Figure 2-2
Rear panel of the chassis
Table 2-1 lists descriptions of the chassis.
Table 2-1
Descriptions of the chassis
No.
Name
Description
1
Rack-mount bracket
Used to fix the chassis to a bench
2
Card slot
Cards are plugged into slots 0–12.
3
Dust-proof mesh
Used to contain the dust-proof cotton to prevent
dust from accessing the device.
4
Power supply card slot
Power supply cards are plugged into slots POWER1
and POWRE2.
5
Tab
Used to fix the fan on the chassis
6
Heat dissipation
The fan is installed above the heat dissipating area
to dissipate hot air inside the chassis.
7
Alarm terminal
Four-hole spring terminal supporting one-way
alarm input and one-way alarm output
The DC voltage connected to the alarm
output terminal should not exceed 30 V and
the current should not exceed 1 A. The AC
voltage connected to the alarm output
terminal should not exceed 125 V and the
current should not exceed 0.3 A.
8
Fan power supply interface
Used to supply power to the fan
9
Fan monitoring interface
Used to connect to the fan and monitor its status