Raisecom
iTN2100 (P100R002) Hardware Description
15 PDH and RCMS cards
Raisecom Technology Co., Ltd.
143
Table 15-11
Alarms of the OPCOM3500E-32E1/32E1-BL
Alarm
Cause
Level
E1 LOS alarm
Attenuation of received signals is over great.
The peer sender fails.
The fiber head is unclean or the connector is
improperly connected.
The local receiver fails.
Critical
E1 AIS alarm
Timeslot of the backplane of VC12 corresponding to
the local E1 is faulty or improperly configured.
The E1 channel of the remote PDH device is faulty or
improperly configured.
Minor
15.2.7 Cables
Table 15-12 lists cables of the OPCOM3500E-32E1/32E1-BL.
Table 15-12
Cables of the OPCOM3500E-32E1/32E1-BL
Card
Cable
OPCOM3500E-32E1
CBL-E1-SCSI100M(40)/32BNCF
CBL-E1-SCSI100M(40)/32BNCM
OPCOM3500E-32E1-BL Non-balanced
interface
Balanced interface
CBL-E1-SCSI100M (40)/16RJ45
15.2.8 Specifications
Table 15-13 lists specifications of the OPCOM3500E-32E1/32E1-BL.
Table 15-13
Specifications of the OPCOM3500E-32E1/32E1-BL
Parameter
Value
Dimensions
25 mm (width) × 232 mm (depth) × 240 mm (height)
Weight
< 0.45 kg
Max. power consumption 3 W