Service.
Turn off the stove and shut off the gas supply. Ensure the stove is com-
pletely cold before starting. Rais/attika cannot be held responsible for
injuries arising from touching a hot stove.
Proposed service procedure.
1. Protect the floor by laying down a mat or other covering.
2. Open the door and carefully remove the ceramic logs including em-
bers.
3. Use a vacuum cleaner to clean the burner and perforated sheet.
4. Lift and remove the secondary burners. Lift out the perforated sheet.
5. Vacuum the entire burner.
6. Clean the pilot burner with a soft brush and a vacuum cleaner. The
thermosensors must not be bent or adjusted.
7. Put on the gas supply and check for leaks. Check that the burners
and pilot unit are in good condition and work.
8. Refit the perforated plate
9. Refit embers and ceramic logs.
10. Check the flue gas system and chimney terminal and ensure it is not
blocked.
11. Turn on the stove and check the set pressure.
12. Ensure the stove is safe to use.
13. Check that the door and other seals are in good condition and effec-
tive.
14. Worn components should be replaced with new.
15. Old fuel bed components can be placed in a strong plastic bag,
sealed and disposed along with household rubbish.
Service.
The stove should be inspected by a Gas Safe Registered engineer once a
year. As a minimum, this inspection should ensure that the stove is work-
ing correctly and is safe to use.
UK
Содержание NEXO 100 Classic Gas
Страница 1: ...1 POSITIV N E X O G A S GB UK ...
Страница 34: ...34 ceramic Logs Log 1 Log 2 Log 3 Log 4 Log 6 Log A Log B UK Log 5 ...
Страница 36: ...36 4 3 5 Log 3 Log 4 Log 5 UK ...
Страница 37: ...37 6 A B Log 6 Log A Log B UK ...
Страница 50: ...50 UK ...
Страница 51: ...51 UK ...
Страница 56: ...56 UK ...
Страница 72: ...72 Vertical Roof Terminal with Back outlet for more information see paragraph Location of chimney terminals UK ...
Страница 73: ...73 Horizontal wall Terminal for more information see paragraph Location of chimney terminals UK ...
Страница 85: ...1 2 3 4 5 NEXO Gas 100 120 140 160 185 ...
Страница 86: ...86 1 2 3 4 5 8 6 9 8 7 10 NEXO G Gas 100 120 140 160 185 ...
Страница 87: ...87 ...