8
General Comments
This RAIS/
attika
product is an extremely effective convection gas stove
with a sealed combustion chamber for chimneys with a balanced draught.
It is fitted with a burner with the latest burner technology. It has a var-
iable heat output because it uses a special control system that makes it
possible to use three burners for high output or one burner for a lower
output. One of the burners, called the "Main burner" is located in the
centre of the stove, the second and third burners, called the "Secondary
burners" are located behind the Main burner. The secondary burners can
be switched on and off while the stove is on.
Where there is a natural gas connection, the local gas supply conditions
should be investigated to ensure that the gas composition and pressure
suit the stove's settings.
If the stove is connected to bottled gas, only gas bottles fitted with a gas
regulator (Low pressure regulator) providing the correct gas pressure may
be connected. For this reason, gas bottles without a regulator must not
be connected.
This stove must only be installed, set up and serviced by a Gas safe reg-
istered Engineer. The installation must comply with local and national
Building Regulations and Gas Regulations and the user manual must
be adhered to. The user manual should be left with the customer, who
should keep this for later use. The manual is necessary when the stove is
to be serviced.
Ensure that the chimney terminal is not blocked in any way and is free of
vegetation in the form of trees, bushes etc. and that objects are not rest-
ing against the chimney's terminal or the protection around the terminal.
The door glass should always be cleaned before the stove is turned on
and fingerprints wiped as these can be burned into the glass.
The stove must not be used if the door glass is split, cracked, re-
moved or if the door is open. Do not use the stove if the door
gasket is broken or worn.
General
UK
Содержание NEXO 100 Classic Gas
Страница 1: ...1 POSITIV N E X O G A S GB UK ...
Страница 34: ...34 ceramic Logs Log 1 Log 2 Log 3 Log 4 Log 6 Log A Log B UK Log 5 ...
Страница 36: ...36 4 3 5 Log 3 Log 4 Log 5 UK ...
Страница 37: ...37 6 A B Log 6 Log A Log B UK ...
Страница 50: ...50 UK ...
Страница 51: ...51 UK ...
Страница 56: ...56 UK ...
Страница 72: ...72 Vertical Roof Terminal with Back outlet for more information see paragraph Location of chimney terminals UK ...
Страница 73: ...73 Horizontal wall Terminal for more information see paragraph Location of chimney terminals UK ...
Страница 85: ...1 2 3 4 5 NEXO Gas 100 120 140 160 185 ...
Страница 86: ...86 1 2 3 4 5 8 6 9 8 7 10 NEXO G Gas 100 120 140 160 185 ...
Страница 87: ...87 ...