background image

 

(A)

 

INTRODUCTION 

Your Rainfresh TWIST Drinking Water System uses a premium filtering 
process, providing cleaner, safer, better tasting drinking water for your 
family. It reduces lead, VOC (volatile organic compounds), cysts, 
chlorine, bad tastes and odours (see performance data sheet for 
details)*. The system is designed for installation under the kitchen sink 
and includes a ceramic-disc faucet for dispensing filtered water. 
*

Contaminants reduced by this system are not necessarily in your water.

 

 
The “Twist ON/Twist OFF” design makes cartridge replacement quick 
and easy, using no tools and without having to shut off the water. 
 
The system features a unique electronic monitor (QS1 only) that tracks 
both the gallons used and time in service and triggers a blinking orange LED when either of these limits is 
reached advising you to replace the cartridge. 

 

(B)

 

SAFETY INSTRUCTIONS 

o

 

This filter system is designed for residential point-of use undersink indoor installation only. 

o

 

Protect filter from direct sunlight. 

o

 

If water pressure

 

will at any time exceed the 100 psi maximum, a pressure regulator and water hammer 

arrestor must be installed before the filter to prevent 

potentially damaging shocks caused by high 

pressure. 

Recommended regulator setting is 75 psi / 5.1 bar/ 517 kPa or less. Not intended for 

installation in multi-storey buildings over 4 storeys.  

o

 

Do not subject to freezing temperatures with water inside the unit. If your unit will not be used in winter, 
or will be subject to freezing temperatures, drain unit completely (see “Maintenance” section for details). 

o

 

This system is intended for use with cold water only. DO NOT INSTALL ON HOT WATER. 

o

 

Only use Rainfresh TWIST filter cartridges with this unit. No other filter cartridge will fit or 
function with this system

o

 

Do not lubricate O-rings with petroleum based lubricants. Only food-grade silicone (Dow 111 
compound) should be sparingly used. 

o

 

Do not

 

clean unit with organic solvents such as those found in sprays for cleaning products or 

insecticides as these may cause cracking or crazing and lead to failure and leakage. 

o

 

Installation of this unit may involve some water spillage. Keep an ample supply of paper towels or an 
absorbent cloth handy. 

 

(C)

 

TECHNICAL SPECIFICATIONS 

MODEL 

QS1, QS1X 

Rated service flow 

0.75 US GPM (2.83 LPM) 

Inlet/outlet  

¼” OD tube 

Operating Temp 

4°C (39°F) min. to 38°C (100°F) max.  

Note: 

For cold water use only. 

Working Pressure* 

40 psi (min) to 100 psi (689 kPa) max 

Dimensions (excluding faucet) 

12.5”H x 3”W x 3” D 

Chrome faucet 

Included 

Filter cartridge life 

375 US Gal (1,324 L) or 6 months for model QS1 
250 US Gal (946L) or 6 months for model QS1X 

* Install a pressure regulator and water hammer arrestor if pressure exceeds maximum rating at any time. 

Note: 

If 

daytime pressure is over 80 psi, night time water pressure may exceed pressure rating. 

Fig 1 

Содержание Twist QS1

Страница 1: ...ndard B483 1 to NSF ANSI Standard 53 for reduction of lead VOC and Cyst e g Cryptosporidium Giardia to NSF ANSI Standard 42 for reduction of chlorine taste odour and to NSF ANSI 372 for low lead requi...

Страница 2: ...multi storey buildings over 4 storeys o Do not subject to freezing temperatures with water inside the unit If your unit will not be used in winter or will be subject to freezing temperatures drain un...

Страница 3: ...p 1 Mounting the Faucet Faucet may be installed in hole in sink if available or in counter top Note The faucet may also be installed in the sink sprayer hole if available 1 Position faucet on counter...

Страница 4: ...embly is level Note If wall is too thin to accept screw then use round head nuts and bolts not supplied to mount head assembly Step 4 Connecting the faucet Measure the tubing required to connect fauce...

Страница 5: ...Measure and cut remaining length of plastic tubing to connect saddle valve to INLET AcculinkTM fitting To connect tube to the saddle valve slide compression nut 726 0 and compression sleeve 1008 3 ont...

Страница 6: ...turn left and lower it away from head while holding it vertically to retain water Empty the old cartridge in the kitchen sink by holding it upside down and discard Use a dry absorbent cloth or a paper...

Страница 7: ...g out These will clear out if you leave the water standing for a few seconds and are harmless After a few days of use the bubbles will slowly clear away The cartridge came undone from the head on it s...

Страница 8: ...nt This warranty does NOT cover and is intended to exclude any liability on the part of Envirogard for any incidental damages consequential damages labour charges or any other costs incurred in connec...

Страница 9: ...SA B483 1 selon la norme 53 NSF ANSI pour la r duction le plomb le COV les kystes par ex cryptosporidium et giardia selon la norme 42 NSF ANSI effets esth tiques pour la r duction du chlore le go t et...

Страница 10: ...u l int rieur du syst me Si vous n utilisez pas votre syst me en hiver ou s il est expos des temp ratures inf rieures 0 C videz le voir la section Entretien pour plus de d tails Ce syst me est destin...

Страница 11: ...du robinet Le robinet peut tre install sur le rebord de l vier ou sur le comptoir Remarque le robinet peut aussi tre install dans un trou de douchette le cas ch ant 1 Le robinet doit tre install pr s...

Страница 12: ...des crous non compris tape 3 Raccordement du robinet Mesurez la distance entre le robinet et le raccord AcculinkMC de sortie blanc de la t te du filtre puis coupez un bout de tuyau de plastique 1009...

Страница 13: ...nstant Mesurez la distance entre la soupape trier et le raccord Acculink d entr e gris et coupez le tuyau la longueur appropri e Glissez l crou 726 0 la bague 1008 3 et le manchon 1603 du raccord comp...

Страница 14: ...ant et choisir un produit Remarque Il n est pas n cessaire de couper l eau pour changer les cartouches Pour remplacer la cartouche voir fig 9 Tournez la cartouche d un quart de tour vers la gauche et...

Страница 15: ...condes Ce ph nom ne dure pendant quelques jours apr s le remplacement de la cartouche D branchement soudain de la cartouche Caus par une pression d eau excessive ou des coups de b lier dans les tuyaux...

Страница 16: ...te garantie Envirogard ne peut tre tenue responsable d aucun dommage indirect y compris les frais de main d oeuvre et tout autre frais d coulant de l achat de l installation de l entretien ou de la r...

Отзывы: