Programming and Operation,
continued
33
9. Use the
right arrow
to move to the
Limit
field
and select
OK
to activate it.
10. Use the
up
and
down arrows
to set the limit and
select
OK
.
11. Use the
right arrow
to move to the
second
alarm
field and select
OK
to activate it.
12. Use the
up
and
down arrows
to choose between
the
Leak
and
Disable
and select
OK
.
Note
: If you choose
Disable
, select
OK
and then
select - to exit the screen.
13. If you choose
Leak
, select
OK
.
14. Use the
right arrow
to move to the
Limit
field
and select
OK
to activate it.
15. Use the
up
and
down arrows
to set the limit and
select
OK
.
16. Use the
right arrow
to move to the
Action
field
and select
OK
to activate it.
17. Use the
up
and
down arrows
to decide what
action you want to take place if the leak
threshold is reached and select
OK
.
18. Use the
right arrow
to move to the
Object
field
and select
OK
to activate it.
19. Use the
up
and
down arrows
to choose amongst
Decoder, Schedule or Pump to be affected by the
defined alarm condition and select
OK
.
20. Use the
right arrow
to move to the
Object ID
field and select
OK
to activate it.
21. Use the
up
and
down arrows
to choose the
specific Decoder, Schedule or Pump to be
affected by the defined alarm condition and
select
OK
.
22. Select - to return to the Main Menu.
Setting up an auxiliary sensor
An auxiliary sensor works with rain or alarm
sensors. If the rain sensor
is installed far from the
controller or if your system uses a pump alarm,
you will also need an auxiliary sensor activated by
a sensor decoder. Remember, auxiliary sensors
can only tell if a switch is
open
or
closed
. Once an
auxiliary sensor activates, irrigation stops.
1. From the
Sensor Decoder
menu, move the
indicating arrow
to
5. Aux. Sensor Decoder
Address
and select
OK
. The two alternating
blinking
markers
indicate the
Sensor Decoder
Address
field is ready for you to program in the
Address
.
2. Use the
up
and
down arrows
to match
the
Decoder
your system is using for the
Auxiliary Sensor
.
Note:
The
Address
should be recorded on the
irrigation drawings.
3. Select
OK
to store the
Address
and move the
markers
to the
Active
field. A blinking black
box
indicates the field is ready for you to program.
Not Install
is the default setting.
4. Use the
up
and
down arrows
to select either
Normally open
or
Normally closed
.
Note:
Select
Normally open
if the auxiliary sensor
is open all the time. Select
Normally closed
if the
auxiliary sensor opens only when it receives a signal.
5. Select
OK
to return to the
Sensor Decoder
menu.
6. Moving the
indicating arrow
to
6. Return
, and
selecting
OK
, or selecting
minus (-)
returns you
to the
Set-up Data
menu.