Appendix III
97
Master Valve and Pump Set-up Tips
To supply water to the various valves located throughout an irrigation area, systems use either a master valve or
master pump. By recognizing a specific
Address
and switch code, the controller sends a signal telling the decoder
when to activate the valve or pump. The switch code can vary depending on how your system was installed.
Below, we will cover some of the more common installations.
Using a Field Decoder With a Pump
In this installation, a field decoder attaches to a pump using a relay. Rain Bird
®
recommends you use
Relay-100
.
Please see the illustration below. When setting up the controller, enter the field decoder
Address
in the pump
Address
field. The switch code for the above
Relay-100
is
4FFA20
.
With the above setup, the flow sensor monitors the flow rate, sending the information to the controller. Once the
flow exceeds the maximum rate during irrigation, and an alarm flow or leakage schedule is set, the controller will
automatically shut off the pump and all the decoders and valves.
Master Pump
RELAY-100
Field Decoder
Two-Wire
Communications
Cable
Water
Line
MDC Controller
FLOW
Sensor
Sensor Decoder