Integrated Sensor System

TM

 (ISS)

Installation, Programming

& Operation Guide

Содержание ISDL-2400

Страница 1: ...Integrated Sensor SystemTM ISS Installation Programming Operation Guide...

Страница 2: ...communications However there is no guarantee that interference will not occur in a particular installation If the equipment does cause harmful interference to radio or television reception which can b...

Страница 3: ...enna 6 Soil ManagerTM Software 6 Programming the ISDL 2400 Data Logger 7 Programming Overview 7 Auto Sensor 8 Sensor Addresses 8 Sensor Types 8 Soil Data 8 Last Reading 8 Next Reading 8 Auto Basic 9 C...

Страница 4: ...ensor Reading 24 Manual Radio 26 Radio Status 26 Last Wake 26 Next Wake 26 Last SYNC 26 Link Status 26 Manual Radio Wake 27 System Reset 28 Reset 28 Factory Defaults 28 Reset 28 Factory Defaults 29 SD...

Страница 5: ...Date Format 40 Hour Format 40 Select Language 41 Set Date Time 42 Select Date Format 44 Select Hour Format 45 Upgrade Firmware 46 Manual Radio 48 Radio Status 48 Last Wake 48 Next Wake 48 Last SYNC 48...

Страница 6: ...Installation Tools Required 70 Sensor Installation Overview 72 Sensors 72 Wire Paths 72 Valve Boxes 72 Sensor Installation 74 Wire Path Installation 75 Valve Box Installation 76 Data Logger and Repea...

Страница 7: ...analyzes data to determine optimum watering requirements that match specific target conditions across the site Battery powered system components allow ultimate flexibility for soil monitoring data co...

Страница 8: ...real time soil data moisture temperature and salinity levels at various locations on the irrigation site Wireless Data Loggers record and transmit soil data over a Wireless Mesh Network Wireless Repea...

Страница 9: ...oil conditions The sensors do not require calibration and provide accurate readings immediately after installation Sensors connect to an ISDL 2400 Data Logger using a three conductor AWG 18 gauge irri...

Страница 10: ...intervals or can operate in a stand alone mode to provide instant real time soil readings from the sensors Each ISDL 2400 supports up to 18 soil sensors on two channels nine sensors per channel Contro...

Страница 11: ...rk The ISS supports a maximum of 40 Wireless Repeaters over the entire network A maximum of 7 hops allowed from end node to Wireless ISG 2400 Gateway router Unobstructed line of sight range is at leas...

Страница 12: ...esh network and the Central Control Software The Gateway communicates with the network of ISDL 2400 Data Loggers and ISR 2400 Repeaters through a roof mounted radio antenna and routes data to and from...

Страница 13: ...tage and wireless link quality are sent to the Central Control Software Soil Manager at regular intervals When the dial is in any other switch position radio communication with the network continues b...

Страница 14: ...for each sensor Last Reading The elapsed time since the last sensor reading is displayed Next Reading The time remaining until the next sensor reading is displayed Turn the dial to Auto SENSOR The Aut...

Страница 15: ...MED or HIGH Last Sync The elapsed time since the last Soil Managernetwork update is displayed Radio Status The current status of the radio is displayed as Awake Sleep or Setup NOTE Details on Radio Mo...

Страница 16: ...d time can be re entered manually but it is recommended to let the Soil Managerupdate the values automatically during the next network sync Date Format Three different date formats are available MM DD...

Страница 17: ...BASIC Sample Rate The sample rate determines how often the ISDL 2400 records soil data from the sensors When the radio is on the sample rate of 2 120 minutes is controlled by the Soil Manager If commu...

Страница 18: ...cted Press the or buttons to set the current year then press NEXT Hour is selected Press the or buttons to set the current hour then press NEXT Set Date Time Used to manually enter system date and tim...

Страница 19: ...ure screen appears Press the UP or DOWN button to select Date Format then press OK The Date Format screen appears Press the UP or DOWN button to select the desired date format then press OK When nishe...

Страница 20: ...ect Hour Format then press OK The Hour Format screen appears Press the UP or DOWN button to select 24 Hour or 12 Hour then press OK When nished turn the dial to Auto SENSOR or BASIC Select Temperature...

Страница 21: ...sensors measure soil conditions NOTE The sample rate will need to be manually set if the radio is off or network communication is lost Turn the dial to CONFIGURE DATA LOGGER The Configure screen appea...

Страница 22: ...K The Update Firmware screen appears The Confirm firmware update message is displayed Press the 2 and 4 buttons together for 3 seconds to initiate the update The Update Firmware message displays Check...

Страница 23: ...creen NOTE An alternate procedure to upgrade the firmware is to turn off the power switch inside the ISDL turn the dial to Configure Data Logger insert the SD card with the new firmware file and turn...

Страница 24: ...rer is 0 Remove Sensor The ISDL 2400 removes the address of a selected sensor from the Data Logger database and the removed address is made available to new sensors Query Channel Sensor Address This f...

Страница 25: ...Sensor Setup screen appears Press the UP or DOWN button to select Add Ch 1 or Ch 2 then press OK The Add Sensor screen appears Press the UP or DOWN button to select an available slot then press OK The...

Страница 26: ...When nished turn the dial to Auto SENSOR or BASIC Remove Sensor The ISDL 2400 removes the address of a selected sensor from the Data Logger database and the removed address is made available to new se...

Страница 27: ...n can be pressed to change the sensor address back to 0 This should always be pressed when installing a new sensor on the ISDL to verify the address is 0 When nished turn the dial to Auto SENSOR or BA...

Страница 28: ...e Sensor Setup screen appears Press the UP or DOWN button to select Scan Sensors then press OK The Sensor Scan screen appears and begins scanning When complete the number of installed sensors and the...

Страница 29: ...this page intentionally left blank...

Страница 30: ...can be found in the Appendix section page 89 Soil Data Last measured moisture temperature and salinity levels are displayed for each sensor Last Reading The elapsed time since the last sensor reading...

Страница 31: ...00 09 35 00 05 25 READ Sensor 2 Type 3 63 8 F 18 3 M 0 21 dS The screen shows Reading while taking new soil measurements Manual Sensor Last Next 00 09 35 00 05 25 Reading 2 READ Sensor 2 Type 3 63 8 F...

Страница 32: ...p to Awake is displayed Next Wake The time remaining until the next scheduled Wake is displayed Last SYNC The elapsed time since the last sync command from the Soil Manager is displayed Link Status Th...

Страница 33: ...Turn the dial to MANUAL RADIO The Manual Radio screen appears If the Radio Status is SLEEP press the WAKE button to change the status of the radio to Awake NOTE Radio will wake for approximately 20 3...

Страница 34: ...o default factory values NOTE After the Factory Default function is performed all sensors are un installed from the data logger Each connected sensor keeps its last assigned address but no sensors ins...

Страница 35: ...BASIC Factory Defaults This function resets all system settings except date and time to default factory values Turn the dial to SYSTEM RESET The System Reset screen appears Press the UP or DOWN butto...

Страница 36: ...dy is displayed Card Capacity The capacity of the installed SD card is displayed in MB megabytes Card Free Space The amount of available space on the installed SD card is displayed in MB megabytes NOT...

Страница 37: ...factory default address is 0 Features ISDL Version 1 0 Radio Version 804B Node 13A200 403B6CE2 Host 13A200 4033F656 DIAGNOSTIC Diagnostic Tests The following diagnostic tests are available Diagnostic...

Страница 38: ...nished turn the dial to Auto SENSOR or BASIC The Enter Password message is displayed Enter 4132 If the correct password is not entered after 10 seconds Invalid password or timeout is displayed Press R...

Страница 39: ...rsion 1 0 Radio Version 804B Node 13A200 403B6CE2 Host 13A200 4033F656 DIAGNOSTIC The Enter Password message is displayed Enter 4132 If the correct password is not entered after 10 seconds Invalid pas...

Страница 40: ...creen appears Press M TEST key to start manufacturing functional test is displayed Press M TEST Run Diagnostic Test 3 Performs a manufacturing functional test that displays the status of various ISDL...

Страница 41: ...nsor System Testing message is displayed while conducting the test When complete the MFG TEST RESULTS screen appears Press RETRY to conduct the test again if desired When nished turn the dial to Auto...

Страница 42: ...Integrated Sensor System O Position This position sets the ISDL 2400 into low power mode and keeps the internal clock and microprocessor running Sensor readings and radio communications are terminate...

Страница 43: ...ally The LCD on the front panel provides access to a variety of programming functions such as setting date and time or upgrading firmware NOTE If the ISR 2400 is not powered on open the front panel Se...

Страница 44: ...radio prepares to listen to network commands Home 09 23 2010 03 28 45 Vbat HIGH Link HIGH Last SYNC Radio Status Awake 01 39 35 MENU WAKE Home Screen The Home screen displays basic system information...

Страница 45: ...o status view SD card information conduct range tests or perform diagnostic tests Home Press HOME to return to the Home screen Programming Buttons Use the UP DOWN and OK buttons to make programming se...

Страница 46: ...settings or sensor configuration Con guration This option provides the capability to manually change system settings Language Eight different languages are available English Italian Spanish Portuguese...

Страница 47: ...ress the UP or DOWN button to select Language then press OK The Select Language screen appears Press the UP or DOWN button to select the desired language then press OK Select Language Seven different...

Страница 48: ...n appears with the month selected Press the or button to set the current month then press NEXT Day is selected Press the or button to set the current day then press NEXT Set Date Time Used to manually...

Страница 49: ...ute is selected Press the or button to set the current minute then press DONE Year is selected Press the or button to set the current year then press NEXT Hour is selected Press the or button to set t...

Страница 50: ...23 2010 03 28 45 Vbat HIGH Link HIGH Last SYNC Radio Status Awake 01 39 35 MENU WAKE The Menu screen appears Press the UP or DOWN button to select Configuration then press OK The Configure screen app...

Страница 51: ...010 03 28 45 Vbat HIGH Link HIGH Last SYNC 01 39 35 Radio Status Awake MENU WAKE The Menu screen appears Press the UP or DOWN button to select Configuration then press OK The Configure screen appears...

Страница 52: ...U button Home 09 23 2010 03 28 45 Vbat HIGH Link HIGH Last SYNC Radio Status Awake 01 39 35 MENU WAKE The Menu screen appears Press the UP or DOWN button to select Configuration then press OK The Conf...

Страница 53: ...ER OFF Updating firmware NOTE Do not turn off power to the ISR 2400 when updating firmware When completed the Rain Bird splash screen is briefly displayed before a return to the Update Firmware screen...

Страница 54: ...Wake The time remaining until the next scheduled Wake is displayed Last SYNC The elapsed time since the last Soil Managerupdate is displayed ON OFF Toggles between ON and OFF depending on the power st...

Страница 55: ...o screen appears Manual Radio Status Last Wake Next Wake Last SYNC HOME OFF WAKE Awake 00 00 41 00 00 53 01 39 35 NOTE If required press OFF or ON to cycle power to the radio Press WAKE to change the...

Страница 56: ...button to select System Reset then press OK The System Reset screen appears Press the UP or DOWN button to select Reset then press OK System Reset This option performs a system reset or returns syste...

Страница 57: ...51 Integrated Sensor System When completed the Rain Bird splash screen is briefly displayed before a return to the Home screen Rain Bird ISR 2400 Repeater...

Страница 58: ...s the MENU button Home 09 23 2010 03 28 45 Vbat HIGH Link Last SYNC Radio Status Awake 01 39 35 MENU WAKE The Menu screen appears Press the UP or DOWN button to select System Reset then press OK The S...

Страница 59: ...t be accurately displayed if the SD card has been used in other digital media such as a digital camera or music player An SD card reader and personal computer can be used to check the free space Check...

Страница 60: ...ures are found on pages 66 69 in the Installation section of this manual NOTE Do not conduct range tests when the mesh network is operating This feature is intended for installation or troubleshooting...

Страница 61: ...default address is 0 Features ISR Version 1 0 Radio Version 804B Node 13A200 403B6CE2 Host 000000 00000000 DIAGNOSTIC BACK HOME Diagnostic Tests The following diagnostic tests are available Diagnosti...

Страница 62: ...e Menu screen appears Press the UP or DOWN button to select Special Features then press OK The Features screen appears Press and hold the second and third buttons until the Diagnostic screen appears F...

Страница 63: ...stem The Diagnostic 1 screen and test results are displayed Diagnostic 1 EXIT WAKE Radio Status RSSI Battery Packet Awake 78 dBm 4 89 0 0 MED HIGH NOTE If necessary press WAKE to change the radio stat...

Страница 64: ...Awake 01 39 35 MENU WAKE The Menu screen appears Press the UP or DOWN button to select Special Features then press OK The Features screen appears Press and hold the second and third buttons until the...

Страница 65: ...reen appears press the button Diagnostic 1 EXIT WAKE Radio Status RSSI Battery Packet Awake 78 dBm 4 89 0 0 MED HIGH The Diagnostic 2 screen and test results are displayed NOTE If necessary press WAKE...

Страница 66: ...he Features screen appears Press and hold the second and third buttons until the Diagnostic screen appears Features ISR Version 1 0 Radio Version 804B Node 13A200 403B6CE2 Host 13A200 4033F656 DIAGNOS...

Страница 67: ...tus RSSI Battery Packet Awake 78 dBm 4 89 0 0 MED HIGH The Diagnostic 3 screen appears Press M TEST key to Start manufacturing functional test is displayed Press M TEST Testing is displayed while cond...

Страница 68: ...this page intentionally left blank...

Страница 69: ...lling the ISS for the first time it is recommended that the Installation Checklist be used as a step by step guide to the installation process For your convenience a check off box is provided for each...

Страница 70: ...east two other Repeaters to establish an alternate signal path Each Repeater should be installed within range of at least two other Repeaters The Gateway antenna should be within range of at least two...

Страница 71: ...le Maintenance Building Antenna Data Logger Repeater DL R GA DL R GA R R R R DL DL DL DL DL DL DL DL R Key R R NOTE Each data logger must be in direct range of at least two repeaters or one repeater a...

Страница 72: ...2400 ISR 2400 pair Verify at least two ISR 2400 s are within range of the base radio antenna Use the Site Survey map and the GPS locator to pinpoint proposed unit locations The locations can be adjust...

Страница 73: ...wake MENU WAKE The Menu screen appears Press the UP or DOWN button to select Range Test press OK The Range Test screen appears Press the UP or DOWN button to highlight Transmit Mode do not press OK Ea...

Страница 74: ...ode Radio Status RSSI 71 dBm Rx Tx 18 BACK CLEAR HOME The following screen is now displayed on ISR 1 Range Test Awake High 18 Loopback Mode Radio Status RSSI 72 dBm Packet count BACK CLEAR HOME Observ...

Страница 75: ...Values RSSI Value dBm Relative Strength 92 to 85 Low 85 to 80 Medium Above 80 High Table 4 Packet Ratio RX TX Value Acceptable 90 100 Yes 0 90 No NOTE The RX TX value is displayed on the LCD as a rat...

Страница 76: ...or any cable pulling equipment Sod cutter with mole kit vibratory plough etc 6 Three conductor AWG 18 gauge irrigation cable 7 Rain Bird DB series Wire Connectors 8 Valve Boxes 6 Required tools and m...

Страница 77: ...71 Integrated Sensor System Figure 7 Installation Tools 1 11 12 9 8 7 6 5 4 3 2 10 13 14 15 16...

Страница 78: ...the root zone and a lower sensor to monitor salinity conditions NOTE Sensors must be addressed before installation Prior to burial connect each sensor one at a time to the data logger and take a readi...

Страница 79: ...DL 2400 Wireless Data Logger RADIO BASIC Auto Manual SPECIAL FEATURES SYSTEM RESET SENSOR SETUP CONFIGURE DATA LOGGER SD CARD INFO SENSOR SENSOR OFF ISDL 2400 Ch 1 Wire Path Valve Box Sensor Cable Sen...

Страница 80: ...should be placed deep enough to avoid damage from deep tine aerification Set sensor s into the bottom of the hole and run each sensor cable into the trench and back to valve box location Push one sen...

Страница 81: ...with blade mole kit or a vibratory plough lay cable around the green deep enough to avoid damage from aerification as shown in Figure 14 Start at either the data logger or the furthest valve box loca...

Страница 82: ...g a wire stripper and Rain Bird DB series wire connectors connect the sensor cable to the wire path as shown Table 5 Cable Wires Cable Data Power Ground Wire Path Green Red White TSM 3 Type 3 Blue Red...

Страница 83: ...400 or ISR 2400 and are required for installation If anything is missing please contact your distributor before proceeding 1 ISDL 2400 or ISR 2400 unit 2 Ribbon Cable 3 Antenna 4 Antenna Rubber O Ring...

Страница 84: ...le conduit The unit must be mounted at least 5 ft above grade to ensure wireless network communication Attach the mounting bracket using appropriate hardware for the location surface Insert one of the...

Страница 85: ...it makes installation easier the front door and front panel can be removed and then re attached when installation is complete Insert the remaining three machine screws through the mounting holes on th...

Страница 86: ...he rubber o ring provided over the brass terminal post on top of the unit then screw the antenna securely to the post The connection should be tight For ISR 2400 Repeater set the internal ON OFF switc...

Страница 87: ...oute wire paths through the conduit and up through the knock out hole in the bottom of the ISDL 2400 unit Connect the wires to the Ch 1 or Ch 2 posts and label each wire clearly for future reference S...

Страница 88: ...m wireless network reception This can be on the roof the building where the central workstation is located or else another appropriate location To Install the Antenna Install the antenna according to...

Страница 89: ...tenna Connector jack on the ISG 2400 Gateway Connect the USB cable to the Gateway and an open USB port on the workstation computer preferably on the back of the computer to prevent accidental removal...

Страница 90: ...this page intentionally left blank...

Страница 91: ...iod interval and the length of time that the radio mode changes to Awake is controlled at the central workstation by a sync command from the Soil Manager Several programming features of the ISDL 2400...

Страница 92: ...ies The battery levels are displayed at each unit Vbat and sent to the central workstation Estimated minimum battery life is twelve months in 20 C 68 F environment assuming 100 readings per day To rep...

Страница 93: ...unlock the door of the unit with the supplied key Then open the door of the unit and swing it to the left Open the front panel and swing it open to the left exposing the interior of the unit To remove...

Страница 94: ...se while operating or installing the ISSTM General Troubleshooting Table 7 General Troubleshooting Problem Solution No display on LCD Press backlight button If display doesn t light up check batteries...

Страница 95: ...Step 5 if the error does not clear Step Action 5 Check the wiring connections to the terminals inside the ISDL 2400 a Inspect wires for open and or short circuits b Verify wires are connected to the c...

Страница 96: ...Value Details Radio Status Awake or Sleep Shows current radio status Last Wake hr min sec Elapsed time since last wake Next Wake hr min sec Time until next wake Last SYNC hr min sec Elapsed time sinc...

Страница 97: ...Figure 9 Type 3 Sensor Installation 74 Figure 10 Wire Path Installation 75 Figure 11 Valve Box Wiring Diagram 76 Figure 12 Box Contents 77 Figure 13 Antenna Installation 82 Figure 14 ISG 2400 Gateway...

Страница 98: ...this page intentionally left blank...

Страница 99: ...1000 4 2 EN61000 4 3 Model Numbers Data Logger ISDL 2400 EN61000 4 4 Repeater ISR 2400 EN61000 4 6 Soil Sensors TSM 1 TSM 3 ETSI EN 301 489 1 ETSI EN 301 489 17 I the undersigned hereby declare that t...

Страница 100: ...opyright 2011 by Rain Bird Corporation All rights reserved This material may not be published or reproduced without permission Rain Bird Integrated Sensor System and Soil Manager are registered tradem...