Screw Terminal Definition
There are five Screw Terminals located under the Screw Terminal Cover on
the straight edge of every RealTrax Switch. The positions of the Screw
Terminals on a Right-Hand Switch mirror those on the Left-Hand Switch (see
figure 1b, below).
Figure 1b:
Straight AC Screw Terminal:
This Screw Terminal is the input connection
of AC power that causes the points (rails that shift positions) to
align with the straight direction of travel. The Straight AC Screw
Terminal may be connected to either the GREEN wire of the
Remote Switch or an external AC power source.
Curved AC Screw Terminal:
This Screw Terminal is the input connection of
AC power that causes the points (rails that shift positions) to align
with the curved direction of travel. The Curved AC Screw Terminal
may be connected to either the RED wire of the Remote Switch or
an external AC power source.
ACG (Common) Screw Terminal:
This Screw Terminal is the electrical
ground connection for all power and Remote Switch inputs.
Auxiliary Power AC In Screw Terminal:
This Screw Terminal is the input
connection of an outside power source's AC (powered) terminal.
(Note: the jumper between the Auxiliary Power AC In Screw
Terminal and the Track AC Out Screw Terminal must be removed
to operate your switch via auxiliary power).
Track AC Out Screw Terminal:
This Screw Terminal is connected directly
to track power (center rail).
Curved AC Screw Termial
ACG (Common) Screw Terminal
Aux Power AC In Screw Terminal
Track AC Out Screw Terminal
Straight AC Screw Terminal
6