The  user  is  NOT  ALLOWED  to  carry  out  any  kind  of  repair  
of  the  device  himself/herself.  Any  attempt  of  scale 
modification, repair etc., by unauthorized persons, will result 
with  loss  of  validity  of  manufacturer-issued  certificates, 
declarations and warranty. 

 

 

5. RECYCLING 

 

WLY  scales  must  be  recycled,  they  are  not  to  be  treated  as  a  regular 
household  waste.  Scales  to  be  decommissioned  must  be  decommissioned  
in accordance with valid legal regulations. 

 

 

 

 

6. MECHANICAL DESIGN 

 

WLY scale is a 1-load-cell device intended to carry out fast and precise mass 
measurement of up to 120 kg loads. Its characteristic feature is a platform with 
one  load  cell  only.  The  platform  is  equipped  with  a  stainless  steel  weighing 
pan.  Depending  on  a  scale  model,  the  cross  and  base  are  made  of  either 
stainless steel or powder-coated steel.  

 

1-load-cell scale design, the main components 

 

 

 

1-load-cell scale design, the main components: 

1- 

– weighing pan, 2 – cross, 3 - load cell, 4 - base. 

Содержание WLY Series

Страница 1: ......

Страница 2: ...2 NOVEMBER 2020...

Страница 3: ...WLY 10 D2 10kg 0 1g 195x195mm WLY 12 F1 R 12kg 0 2g 300x300mm WLY 12 F1 K 12kg 0 2g 300x300mm WLY 20 D2 20kg 0 1g 195x195mm WLY 30 F1 R 30kg 0 5g 300x300mm WLY 30 F1 K 30kg 0 5g 300x300mm WLY 60 C2 R...

Страница 4: ...r and UV radiation substances causing chemical reactions The device must not be operated in hazardous areas endangered with explosion of gases and in dusty environments In case of damage immediately u...

Страница 5: ...chnical Specifications 11 6 4 2 I O Schematic Diagrams 11 6 5 Operation Panel 12 7 INSTALLATION 13 7 1 UNPACKING AND INSTALLATION 13 7 1 1 WLY D2 Series 13 7 1 2 WLY C2 WLY F1 Scales 13 7 2 Levelling...

Страница 6: ...ects of unclear origin and means of their elimination can only be realized with assistance of the manufacturer and user representatives C RADWAG does not bear any responsibility for damage or losses r...

Страница 7: ...r for all surfaces we recommend carrying out tests Do not use cleansers containing abrasive substances 3 2 Cleaning Stainless Steel Components Avoid using cleansers containing any corrosive chemicals...

Страница 8: ...issioned must be decommissioned in accordance with valid legal regulations 6 MECHANICAL DESIGN WLY scale is a 1 load cell device intended to carry out fast and precise mass measurement of up to 120 kg...

Страница 9: ...9 6 1 Dimensions Dimensions of WLY D2 scale Dimensions of WLY F1 scale Dimensions of WLY C2 scale...

Страница 10: ...S232 Connector RS232 DB9 M connector male front Pin2 RxD Pin3 TxD Pin4 5 V DC Pin5 GND RS232 DSUB15 F connector female front Pin8 TxD2 Pin9 5VDC Pin10 GND Pin13 RxD2 6 4 Inputs Outputs Standard C32 sc...

Страница 11: ...Technical Specifications Output parameters Output quantity 4 Output type Solid state relay Cable cross section 0 14 0 5 mm 2 Maximum output current 0 5 A DC Maximum output voltage 30 VDC Input paramet...

Страница 12: ...ess to switch the scale ON OFF Press to zero the scale Press to tare the scale Press to send the weighing result to a printer or a computer Press to enter the menu function button Programmable key Pro...

Страница 13: ...en surface Keep it far away from any sources of heat C Install the weighing pan and the indicator holder in accordance with the figure below 7 1 2 WLY C2 WLY F1 Scales Take the device out of the packa...

Страница 14: ...diode on indicator housing is turned on Press key it is to be found at the top of the operation panel Mind to keep the key pressed for about 0 7 s Operation system and RADWAG program are loaded this i...

Страница 15: ...buttons Home screen layout 8 1 Top Bar The top bar displays the following information Working mode name and symbol Log in entry Symbol informing that communication with a PC is on Symbol informing tha...

Страница 16: ...mplates is currently displayed In order to switch to a different template drag the workspace screen to the left right respectively 8 4 Function Buttons On screen function buttons are to be found under...

Страница 17: ...s to clear dialog box content Press to enable disable an on screen keyboard Press to read printout template saved to lb file the button becomes active upon USB flash drive connection Press to save the...

Страница 18: ...void applying mechanical shocks Place the loads centrally on the weighing pan eccentricity errors are specified by EN 45501 standard point 3 6 2 In case of eccentric loading make sure that a mass of l...

Страница 19: ...19 11 DIAGRAMS OF CONNECTION CABLES Scale computer cable RS232 Scale printer cable ZEBRA Scale printer cable EPSON...

Страница 20: ...20 I O cable Scale Ethernet cable is a standard network cable terminated with RJ45 connectors on both ends 12 ERROR MESSAGES...

Страница 21: ...21...

Отзывы: