9. Troubleshooting &
Error Messages
Troubleshooting
This section deals with problems that you may encounter that do not provide an error
message. If an error message is displayed, see the next section of this chapter,
Common Error Messages
.
9
9
Symptoms
Possible
cause(s)
Solution
System appears to boot
(evidenced by RUN LED
being on, floppy and hard
disk being accessed) but
provides no video.
Video adapter not fully
seated.
Monitor or cable problem.
Video adapter failure.
EPC-7 cannot talk to
EXM expansion interface.
Remove the video adapter.
Verify that the cable pins are not
bent and the cable is fully seated in
the video adapter. If necessary, try
the monitor on another system to
verify that the monitor is good.
Call RadiSys Technical Support.
Call RadiSys Technical Support.