Chapter 3: Technical Data

Service Manual

39

Platform Management 

Platform management is provided on the EPC-3221 SCB by an on-board intelligent platform 
management (IPM) controller. The IPM controller is capable of monitoring environmental 
sensors on the EPC-3221 SCB and communicating with other IPM controllers in an IPM-
capable chassis.

The monitoring and logging functions of the IPM subsystem are independent of the main 
processors, BIOS, and operating system. This allows devices supporting IPM to communicate 
even when the system is not powered or operational.

Inter-device communication is provided by the Intelligent Platform Management Bus (IPMB) 
which connects all intelligent devices. The Inter-Integrated Circuit (I

2

C) interface enables the 

IPMB and is located in the passive backplane of a chassis.

Intelligent devices communicate general state information and alert information (such as 
warnings or critical conditions) to a centralized management controller, the Baseboard 
Management Controller (BMC). The BMC provides a System Event Log (SEL) for storing 
events generated by IPM devices in the chassis.

Figure 13

 shows an EPC-3221 SCB in a typical platform management environment.

Figure 13. SCB Platform Management

Display

Module

(optional)

Intel

Processor

BMC

Keyboard 

Controller-

Style Interface

IPMI

IPMI

Alarm

Board

(optional)

IPMI

External

Interface

Power

Supplies

IPMI

Fans

System Management Components

IPMI

IPMB

EPC-3221

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание EPC-3221 C1000BX-SVE

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...in USA EPC 3221 RPSDFW3 SCB C1000BX SVE and C1XTN02 Transition I O Module P N 007 01143 0000 October 2000 A system controller board SCB is also known as a single board computer Artisan Technology Gro...

Страница 3: ...tion its officers agents and employees for negligence inexcusable delay breach of warranty express or implied or any other default relating to the item or RadiSys duties to eliminate any errors This w...

Страница 4: ...ht vorgenommen werden Nur qualifiziertes und ausgebildetes Fachpersonal sollte am Inneren des Ger tes arbeiten Beim Installieren und Entfernen von Komponenten ist besondere Vorsicht geboten F r weiter...

Страница 5: ...dio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s expense T...

Страница 6: ...eration Warning This symbol indicates the presence of a potential hazard that can cause personal injury Only qualified and trained electronics service personnel should access the equipment Artisan Tec...

Страница 7: ...Europe Monday Friday 8 30 a m 5 00 p m dial 31 36 5365595 Inspection of Contents Packaging of Product The packaging for this product has been tested to assure that it will withstand responsible handli...

Страница 8: ...he C1XTN02 Transition I O Module 16 Step 4 Attach Peripheral Devices 18 Step 5 Power On the System 20 Step 6 Run the Setup Utility 21 Chapter 3 Technical Data 27 Specifications 28 Pin Signals 30 Perip...

Страница 9: ...lling the SCB 15 Figure 7 Installing the Transition I O Module 17 Figure 8 Peripheral Connectors 19 Figure 9 Setup Utility Main Menu 20 Figure 10 Parallel Port Cable 32 Figure 11 USB Port Cable 32 Fig...

Страница 10: ...Service Manual ix List of Tables Table 1 EPC 3221 SCB Sensors 41 Table 2 Sensor Threshold Descriptions 42 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 11: ...PC 3221 CompactPCI System Controller Board and Optional C1XTN02 Transition I O Module x Service Manual Notes Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 12: ...the equipment go to Chapter 2 6 Steps to Operation on page 9 and return to this chapter later at your convenience This chapter discusses functions and features of the equipment that can be accessed on...

Страница 13: ...e Hitachi H8 3437 system monitoring microcontroller with I2C bus interface Ultra SCSI AGP video 10 100BaseT Ethernet Intel 21150 PCI to PCI Bridge Remote Local Temperature Sensor with SMBus serial int...

Страница 14: ...the following features and components Intel 82559 10 100 Mb sec Ethernet LAN Controller RJ 45 10 100BaseT Ethernet connector on the I O panel Ethernet activity LEDs on the I O panel Rear Transition I...

Страница 15: ...ge Celeron Processor with Heatsink Installed J1 CompactPCI Connector J2 CompactPCI Connector J5 CompactPCI Connector SDRAM Clock Buffer System Reset Button System Reset Header Clock Synthesizer Intel...

Страница 16: ...t Connector Ethernet Activity LED IDE SCSI Activity LED PS 2 Mouse Connector Parallel Port Connector Serial Port 1 Connector Ethernet Link Integrity LED System Reset Button Captive Fastener 2 places I...

Страница 17: ...header Note A cable attaches this header to the parallel port connector on the rear I O panel See Figure 10 on page 32 USB1 header Note A cable attaches this header to the USB1 connector on the rear...

Страница 18: ...ve Fasteners 4 places Guide Pins 2 places Guide Pins 2 places Floppy Drive Header Speaker Header USB1 Header System Monitor Header System Reset Header J5 CompactPCI Connector J4 CompactPCI Connector P...

Страница 19: ...nsions are in compliance with IEEE 1101 1 1101 11 and P1101 11 mechanical requirements More For more information on the components contact SocketModem Features Model Max Data Speed Max Fax Speed Fax C...

Страница 20: ...ch Peripheral Devices Step 5 Power On the System Step 6 Run the Setup Utility This chapter discusses functions and features of the equipment that can be accessed only by qualified and trained electron...

Страница 21: ...rce Follow all safety precautions as outlined by the chassis manufacturer Next Before you install the SCB in a chassis check the switch settings outlined in Step 1 page 12 Handle the components by the...

Страница 22: ...ce Manual 11 Figure 4 Safely Handling the Components Always handle the components by their I O panels or injector ejector handles shown in black Artisan Technology Group Quality Instrumentation Guaran...

Страница 23: ...ess Open Off Crisis Recovery mode disabled default Closed On Crisis Recovery mode enabled SW1 3 CMOS RAM Open Off Normal operation of CMOS RAM default Closed On Factory default values for the Setup Ut...

Страница 24: ...rwise RadiSys Corporation produces a utility to generate a crisis recovery diskette This diskette is to be used only with crisis recovery mode enabled To acquire the proper release BIOS for this produ...

Страница 25: ...ck until the CompactPCI connectors engage the connector body at the backplane Note The alignment pins on the SCB I O panel will be inserted into the alignment holes in the card guide rails 6 Simultane...

Страница 26: ...Fasteners 4 places Alignment Hole Upper Lower Subrack Front Rails Upper Lower Card Guide Rails Upper Lower CompactPCI Passive Backplane EPC 3221 System Controller Board shown with optional CPBRI01Brid...

Страница 27: ...e rails in the chassis subrack Make sure that both injector ejector handles on the transition I O module are in the open position before attempting to insert the board 4 Insert the transition I O modu...

Страница 28: ...pper lower CompactPCI Passive Backplane C1XTN02 Rear Transition I O Module Step 1 Insert the C1XTN02 into the chassis subrack Step 2 First lock the top injector ejector lever then the lower lever on t...

Страница 29: ...onnected in a daisy chain configuration with proper termination Only one of the three SCSI connectors can be used at any one time Floppy Up to two floppy drives can be attached to the XIO Floppy Disk...

Страница 30: ...Parallel Port Header 2 1 SCSI Ultra Fast Wide SCSI Ultra Fast Narrow 49 50 1 2 1 2 39 40 EIDE Headers Primary Secondary Reset 2 1 3 Speaker 1 1 5 USB Header 2 1 33 34 Floppy Disk Drive Header 1 2 3 5...

Страница 31: ...Setup During the POST you can access the Setup Utility Figure 9 to configure the system Figure 9 Setup Utility Main Menu Before using the SCB for the first time you should verify the system settings...

Страница 32: ...the screen that allows you to access the following menus Main Advanced Security Power Boot Server Exit Options and items for these menus are listed in the tables beginning on page 23 Boot and Exit The...

Страница 33: ...a Cache A000 AFFF B000 BFFF Note These items operate in the same manner with any installed video controller whether the on board video controller or an expansion card Advanced PCI Configuration PCI IR...

Страница 34: ...ulti Sector Transfers LBA Mode Control 32 Bit I O Transfer Mode and Ultra DMA Mode do not have default values Values are inserted when the BIOS queries IDE devices Cache Memory Memory Cache L2 Cache E...

Страница 35: ...MA 1 DMA 3 Note This option is displayed shown only if Mode is set to ECP Floppy Disk Controller Enabled Disabled Floppy Disk Controller Base I O Address Primary Secondary Local Bus IDE Adapter Both D...

Страница 36: ...stems If the drive s fail during software installation change this selection and try again Option Sub Menu Item Default Setting Alternate Settings Supervisor Password Is N A Clear Set Display only N A...

Страница 37: ...o Time out N A Disabled 10 Seconds 15 Seconds 30 Seconds 45 Seconds 1 Minute 2 Minutes 4 Minutes 6 Minutes 8 Minutes 10 Minutes 15 Minutes Resume on Modem Ring N A Off On Resume on Time N A Off On Res...

Страница 38: ...modules Instructions for System Battery Replacement Information on Product Identification through the system BIOS This chapter discusses functions and features of the equipment that can be accessed on...

Страница 39: ...ttest available hardware and software configuration to maximize the power supply draw and generate a worst case scenario Despite these efforts the specifications outlined above are only benchmarks and...

Страница 40: ...Addressing Real and protected mode supported Real address mode 20 bit Protected address mode 32 bit on PCI local bus Data Path 64 bit on board processor bus at 66 or 100MHz 32 bit on board PCI bus at...

Страница 41: ...tion Pin Description Pin Description 1 Red 1 Ethernet Transmit TX 1 5 V 2 Green 2 Ethernet Transmit TX 2 USB 3 Blue 3 Ethernet Receive RX 3 USB 12 Video ID 1 4 Ethernet COM 4 Ground 13 Horizontal Sync...

Страница 42: ...tion 35 Data Bit 12 I O 45 Data Bit 5 I O 62 Control Data In 36 Data Bit 13 I O 46 Data Bit 6 I O 63 Request In 37 Data Bit 14 I O 47 Data Bit 7 I O 64 Input Output In 38 Data Bit 15 I O 48 Data Bit P...

Страница 43: ...rror 15 5 Data Bit 1 3 6 Initialize Printer 16 7 Data Bit 2 4 8 Select Input 17 9 Data Bit 3 5 10 Ground 18 11 Data Bit 4 6 12 Ground 19 13 Data Bit 5 7 14 Ground 20 15 Data Bit 6 8 16 Ground 21 17 Da...

Страница 44: ...eT Ethernet RJ 45 connector Y Y 10 100BaseT Ethernet activity LEDs Y N Intel 21150 PCI to PCI Bridge PCI bridge expansion Y N Hitachi H8 3437 system monitoring microcontroller I2C bus interface N Y In...

Страница 45: ...D 25 V I O GND AD 26 7 AD 27 GND AD 28 AD 29 AD 30 6 AD 31 CLK 3 3 V GND REQ 5 GNT GND RST BRSVP1B5 BRSVP1A5 4 INTS INTP V I O Ground BRSVP1A4 3 INTD 5 V INTC INTB INTA 2 BRSVP1E2 BRSVP1D2 BRSVP1C2 5...

Страница 46: ...CSIMSG SCSISEL SCSICD SCSIREQ SCSIIO 2 SCSID8 SCSID9 SCSID10 SCSID11 PBYPASS 1 FAN3 FAN2 OPEN SMBDAT SMBCLK J5 Pin E D C B A 22 EXT_SPKR VCC MODEM_EN GND PBRESET 21 MSCLK MSDAT VCC KBDCLK KBDDAT 20 SM...

Страница 47: ...e mechanically identical to J1 and J2 respectively J4 and J5 are mechanically identical between the SCB and the XIO J1 and J2 connector pairs are mechanically identical for the EPC 3221 and the option...

Страница 48: ...PMCB 22 PMCB 23 PMCB 24 PMCB 25 6 PMCB 26 PMCB 27 PMCB 28 PMCB 29 PMCB 30 5 PMCB 31 PMCB 32 PMCB 33 PMCB 34 PMCB 35 4 PMCB 36 PMCB 37 PMCB 38 PMCB 39 PMCB 40 3 PMCB 41 PMCB 42 PMCB 43 PMCB 44 PMCB 45...

Страница 49: ...sted below Note The Ring Indicator RI signal can be ignored Configuration To enable console redirection 1 Run the Setup Utility See page 21 2 Provide a serial port for console redirection Note A seria...

Страница 50: ...nnects all intelligent devices The Inter Integrated Circuit I2C interface enables the IPMB and is located in the passive backplane of a chassis Intelligent devices communicate general state informatio...

Страница 51: ...gement Bus IPMB to allow other intelligent devices to communicate with the BMC NOTE For additional information on platform management see this Web site http www radisys com service_support This site h...

Страница 52: ...d Voltage 4 CPU 12 V Threshold Voltage 5 CPU 3 3 V Threshold Voltage 6 CPU 2 5 V Threshold Voltage 7 CPU VIO Threshold Voltage 8 CPU Vcore Threshold Voltage 9 VTT Voltage Threshold Voltage 10 CompactP...

Страница 53: ...ading Type Conversion Factor raw CF Eng Normal Value Factory Preset Threshold Design Values Low Non Critical Threshold Low Critical Threshold Low Non Recoverable Threshold High Non Critical Threshold...

Страница 54: ...tatus and Delay These options are defined in the Setup Utility See page 25 Watchdog Status sets the source of the activity monitored by the watchdog timer Enabled the source of the pulse is the CPU Ad...

Страница 55: ...ote Use a grounding wrist strap or other static dissipating device when accessing and handling the equipment 2 Depress the DIMM socket latches outward if required 3 Align the DIMM with the socket Note...

Страница 56: ...Data Service Manual 45 Figure 14 Memory Sockets Figure 15 Installing Memory Modules DIMM 1 Bank 0 DIMM 2 Bank 1 Key Key 1 2 2 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE...

Страница 57: ...tery connector 5 Insert the lower edge of the battery into the connector so that the negative pole bottom surface of the battery engages the negative spring contact of the connector 6 Press the raised...

Страница 58: ...ttery Installation Positive Contact Negative Contact Battery Installed Rear Front Battery Installed Rear Connector Connector Front Side View of Battery Top View of Battery Negative Pole Positive Pole...

Страница 59: ...content of the fields in the BIOS of a typical RadiSys product This identifies a EPC 3221 model system controller board operating at 366 MHz with the SCSI Video and Ethernet optional peripherals The...

Страница 60: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Отзывы: