RC11xx(HP)-TM
RC25xx(HP)-TM
RC17xx(HP)-TM
2016 Radiocrafts AS
RC11xx(HP)/25xx(HP)/17xx(HP)-TM Data Sheet rev. 1.48 Page 28 of 86
2016 Tiny Mesh AS
Radiocrafts
Embedded Wireless Solutions
General Event Packet Format (Packet Type 0x02)
Byte #
Field name
Size
Description
18
Message Detail
1
1 (0x01) Digital Input Change Detected
2 (0x02) Analogue 0 Input Trig
3 (0x03) Analogue 1 Input Trig
6 (0x06) RF Jamming Detected
8 (0x08) Device Reset
9 (0x09) Status Message (IMA)
10 (0x0A) Channel is Busy with Similar System ID
11 (0x0B) Channel is Free
12 (0x0C) Channel is Jammed
13 (0x0D) Other Tinymesh™ System Active on this Channel
16 (0x10) Command Received and Executed (ACK)
11
17 (0x11) Command Rejected, Not Executed (NAK)
11
18 (0x12) Status Message (NID)
19 (0x13) Status Message Next Receiver
19
Message Data MSB
1
Message Detail
Message Data
1
0
9
Configurable content, ref:
IMA MESSAGE DATA FIELD CONTENTS
0: 0 (Default)
1: GPIO Trig Hold register
2: High Byte of 2-byte Pulse Counter
3: High Byte Analogue 2 Input
41
4: High Byte Analogue 3 Input
41
5: Device Connection status:
10
1.
No alternatives on same hop level
2.
Alternatives available, same hop level
3.
Single Gateway
4.
Gateway, alternative available
6: My Locator RSSI
13:Best Triangulating Locator UID0
2,3,8,10,11,
12,13,16,18,19
0
6
Jamming condition duration in minutes
17
0 NAK response from Router- or EndNode
1 (0x01): Bad packet length
2 (0x02): Bad Gateway configuration command
3 (0x03): Bad packet format
4 (0x04): Bad Gateway Command
16 (0x10): Bad Node config string length
17 (0x11): Bad Node config command
18 (0x12): Bad Node packet format
19 (0x13): Bad Node command
20
Message Data LSB
1
Message Detail
Message Data
1
GPIO Trigger source, bit 7-0
9
Configurable content, ref:
IMA MESSAGE DATA FIELD CONTENTS
0: 0
1: 0
2: Low Byte of 2-byte Pulse Counter
3: Low Byte Analogue 2 Input
41
4: Low Byte Analogue 3 Input
41
5: 0
6: 0
13:Best Triangulating Locator RSSI
2,3,10,11,
12,13,18,19
0
6 (0x06)
Hours since jamming condition ended
8 (0x08)
1 (0x01): Power On Reset
2 (0x02): External Reset (RESET input low)
3 (0x03): Reset from Sleep or Config Command
4 (0x04): Forced Reset by command
5 (0x05): Watchdog Reset
16,17
User selected command number
21
Address(ID) Data
4
Message Detail
Message Data
11
ACK and NAK messages from Gateway Device truncated after the Message Data Fields