RC11xx(HP)-TM
RC25xx(HP)-TM
RC17xx(HP)-TM
2016 Radiocrafts AS
RC11xx(HP)/25xx(HP)/17xx(HP)-TM Data Sheet rev. 1.48 Page 72 of 86
2016 Tiny Mesh AS
Radiocrafts
Embedded Wireless Solutions
Absolute Maximum Ratings
Parameter
Min
Max
Unit
Caution!
ESD sensitive devises.
Precaution should be used when handling
the device in order to prevent permanent
damage.
Supply Voltage, VCC
RC11XX-TM
RC11XXHP-TM
RC2500-TM
RC2500HP-TM
RC17XX(HP)-TM
RC1701HP-TM
Supply Voltage, VCC_PA
RC17XXHP-TM
RC1701HP-TM
-0.3
-0.3
-0.3
-0.3
-0.3
-0.3
-0.3
-0.3
3.9
3.6
3.9
3.6
3.9
3.8
5.5
3.8
V
Voltage on any pin
-0.3
VCC+0.3V,
never
exceeding
Max
value
V
Input RF level
10
dBm
Storage temperature
-50
150
°
C
Operating temperature
(RC17xx(HP))
-40
-30
85
85
°
C
Under no circumstance, the absolute maximum ratings given above should be violated. Stress
exceeding one or more of the limiting values may cause permanent damage to the device.
RC11XX(HP)-TM and RC17XX(HP)-TM devices may be powered by Lithium Cell batteries with nominal
output voltage of 3.6V.
Fresh Lithium Cell batteries often have an open circuit voltage higher than their nominal 3.6V rating.
Such cells may be used to power the module as long as the supply voltage never exceeds the absolute
maximum rating of the module. When the module operates in IDLE/RX/TX, the loaded battery voltage
will usually drop to fall inside the module operating voltage range as referenced in table