RC11xx(HP)-TM
RC25xx(HP)-TM
RC17xx(HP)-TM
2016 Radiocrafts AS
RC11xx(HP)/25xx(HP)/17xx(HP)-TM Data Sheet rev. 1.48 Page 59 of 86
2016 Tiny Mesh AS
Radiocrafts
Embedded Wireless Solutions
Parameter
Description
Addr
ess
Argument
Factory
setting
Comment
FW
GPIO 4 trig
Trigger an event on
input level change if
port set as input
28
0-3
30
0
0 = No trig
1 = Rising edge
2 = Falling edge
3 = Both edges
GPIO 5 trig
Trigger an event on
input level change if
port set as input
29
0-3
30
0
0 = No trig
1 = Rising edge
2 = Falling edge
3 = Both edges
GPIO 6 trig
Trigger an event on
input level change if
port set as input
30
0-3
30
0
0 = No trig
1 = Rising edge
2 = Falling edge
3 = Both edges
GPIO 7 trig
Trigger an event on
input level change if
port set as input
31
0-3
30
0
0 = No trig
1 = Rising edge
2 = Falling edge
3 = Both edges
Input De-bounce
De-bounce time in ms
for all inputs
32
0-255
10
GPIO 0 Analogue
High trig High byte
High byte of two byte
High Trig level value
33
0-7
7
GPIO 0 Analogue
High Trig Low byte
Low byte of two byte
High Trig level value
34
0-255
255
GPIO 0 Analogue
Low Trig High byte
High byte of two byte
Low Trig level value
35
0-7
0
GPIO 0 Analogue
Low Trig Low byte
Low byte of two byte
Low Trig level value
36
0-255
0
GPIO 0 Analogue
Sampling Interval
Time between
samplings in 10ms
increments
37
0-255
100
31
GPIO 1 Analogue
High trig High byte
High byte of two byte
High Trig level value
38
0-7
7
GPIO 1 Analogue
High trig Low byte
Low byte of two byte
High Trig level value
39
0-255
255
GPIO 1 Analogue
Low trig High byte
High byte of two byte
Low Trig level value
40
0-7
0
GPIO 1 Analogue
Low trig Low byte
Low byte of two byte
Low Trig level value
41
0-255
0
GPIO 1 Analogue
Sampling Interval
Time between
samplings in 10ms
increments
42
0-255
100
CTS hold time
CTS hold time in 10ms
increments
43
1-255
25
6 (60 ms)
Active on Gateway only.
Locator_Enable
Enable locator function
44
0 or 1
0
UNIQUE_ID0 (UID0)
45
0-255
Unique
UID=
UID3:UID2:UID1:UID0
UID 0 0 0 0 is not allowed
SID=
SID3:SID2:SID1:SID0
SID 0 0 0 0 is not allowed
UNIQUE_ID1 (UID1)
46
0-255
Unique
UNIQUE_ID2 (UID2)
47
0-255
Unique
UNIQUE_ID3 (UID3)
48
0-255
Unique
SYSTEM_ID0 (SID0)
49
0-255
1
SYSTEM_ID1 (SID1)
50
0-255
0
SYSTEM_ID2 (SID2)
51
0-255
0
SYSTEM_ID3 (SID3)
52
0-255
0
Data and configuration interface, UART Serial Port
UART Baud Rate
Baud rate
53
1: 2 400
2: 4 800
3: 9 600
4. 14 400
5: 19 200
6: 28 800
7: 38 400
8: 56 700
9: 76 800
10: 115 200
11: 230 400
5
BE CAREFUL WHEN CHANGING,
AS HOST MAY LOOSE CONTACT
WITH MODULE
!
UART Bits
54
8 or 9
32
8
UART word size
1.21
UART Parity
55
0 or 1
33
0
0= Parity Disable
1.21
UART Stop Bits
56
1 or 2
34
1
Number of stop bits
1.21
Reserved
57
Do not change
31
Analogue Sampling Increments changed from 100ms to 10ms from FW 1.40
32
Value different from 9 will be treated as 8
33
Value different from 1 will be treated as zero (no parity)
34
Value different from 2 will be treated as 1 (Single stop bit)