Page
53
of
60
©
2019 Radiocrafts AS
MBUS User Manual (ver 2.01)
MBUS USER MANUAL
Parameter
Addr
(hex)
MBU
S
3
MBU
S
4
Argument
range
Comment
Default/
Factory Setting
LBT_BO_PERIOD
0x2C
✘
✔
In 10ms steps
0x04
Do not change
LBT_BO_FLAT
0x2D
✘
✔
0x01-0x08
0x03
LBT_MAX_DELAY
0x2E
✘
✔
In 10ms steps
0x4B (75)
Do not change
Data and configuration interface, UART Serial port
UART_BAUD_RATE
0x30
✔
✔
Baud rate.
BE CAREFUL IF CHANGING AS HOST MAY
LOOSE CONTACT WITH MODULE!
Does not take effect until module is re-booted /
reset.
0
0x00
Not used
1
0x01
2400
2
0x02
4800
3
0x03
9600
4
0x04
14400
5
0x05
19200
6
0x06
28800
7
0x07
38400
8
0x08
57600
9
0x09
76800
10
0x0A
115200
11
0x0B
230400
0x05
UART_FLOW_CTRL
0x35
✔
✔
UART flow control
0
0x00
None
1
0x01
CTS only
3
0x03
CTS/RTS
4
0x04
RXTX (RS485)
0x00
DATA_INTERFACE
0x36
✔
✔
Data interface
Sets receiver data format.
First byte is always packet length (except when
using start byte)
0
0x00
MBUS packet with ID and address
1
0x01
Application data only
2
0x02
Reserved
3
0x03
Application data only with ack
(0x00:0x3E)
4
0x04
Add start/stop byte
8
0x08
Add CRC
12
0x0C
Add start/stop byte and CRC
0x00